Key Facts

Interior site cap
10.0 footcandles
Boundary/right-of-way cap
1.0 footcandle
Cap next to residential
0.5 footcandle
Gas station/dealership exception
up to 20.0 footcandles
Measurement height at boundary
5 feet above grade
Governs
all zoning districts

Summary

Clayton County caps how much light can cross onto neighboring property under the Zoning Ordinance's Outdoor Lighting Standards (Sec. 6.36(B)(2)). Light intensity may not exceed 1.0 footcandle at any zoning lot boundary, dropping to 0.5 footcandle where the lot touches a residential district, with a narrow 20.0-footcandle exception for gas station canopies and car dealership display lots.

These county ordinances apply to unincorporated areas of Clayton County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

2.Intensity: The intensity of light within a site shall not exceed 10.0 footcandles within any site and 1.0 footcandles at any zoning lot boundary or street right-of-way line. Where a zoning lot abuts a residential district or existing residential use, the intensity shall not exceed 0.5 footcandles at the zoning lot boundary. The Zoning Administrator may permit a maximum intensity of 20.0 footcandles for lighting under a gas station pump island canopy or within the outdoor sales and display space of an automobile dealership, provided that such lighting is otherwise in compliance with this ordinance.3.Measurement: Light intensity levels shall be measured on the horizontal plane at grade level within the site, and on the vertical plane of any zoning lot boundary or street right-of-way line at a height of five feet above grade level.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 104).

Full Breakdown

The intensity limits apply on top of, not instead of, the shielding and fixture-height standards in the same section. 0 footcandle, so light cannot flood past the edge of the property where it is generated. 5 footcandle measured at that boundary, protecting nearby yards and bedrooms from glare generated by commercial or multifamily lighting. 0 footcandles for lighting under a gas station pump island canopy or within an auto dealership's outdoor sales and display area, provided the installation otherwise complies with the ordinance. Compliance is measured, not eyeballed: intensity readings are taken on the horizontal plane at grade level for the interior of the site, and on the vertical plane at the property line or right-of-way, five feet above grade, which is the height code enforcement uses when a neighbor complains that a floodlight or parking-lot fixture is spilling over the line.

Because the standard is expressed as a hard footcandle ceiling rather than a design guideline, a fixture that is properly shielded under Sec. 36(B)(1) can still violate this subsection if its output measured at the boundary exceeds these numbers.

Violations & Fines

Light trespass complaints are resolved by measurement: Community Development or code enforcement staff take footcandle readings at the property line five feet above grade, and a reading above 1.0 footcandle (0.5 footcandle next to a residential district) puts the property owner or business out of compliance regardless of the fixture's shielding. Noncompliant lighting identified during site plan review will not receive a building permit; lighting installed without that review that later measures over the cap is subject to the county's standard zoning enforcement.

Frequently Asked Questions

How much light can spill onto my neighbor's yard?
Under Sec. 6.36(B)(2), light intensity at any zoning lot boundary cannot exceed 1.0 footcandle, and if the boundary touches a residential district or residential use, that ceiling drops to 0.5 footcandle, measured five feet above grade at the property line.
Is there any exception to the footcandle limits?
Yes, a narrow one. The Zoning Administrator may allow up to 20.0 footcandles for lighting under a gas station pump island canopy or within an automobile dealership's outdoor sales and display area, as long as the rest of the installation still meets the ordinance's shielding and height rules.
How is light trespass measured for enforcement?
Sec. 6.36(B)(3) measures interior site lighting on the horizontal plane at grade level, and boundary or right-of-way lighting on the vertical plane five feet above grade, which is the reading code enforcement uses to confirm whether a fixture exceeds the 1.0 or 0.5 footcandle cap.

Sources & Official References

Other rules in Clayton County

All Clayton County rules

Compare Clayton County to another location·View the Georgia outdoor lighting overview

Get notified when Light Trespass & Shielding in Clayton County, GA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.