Skip to main content
CityRuleLookup

Durham, NC Outdoor Lighting: Light Trespass & Shielding (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Full cut-off height (50+ ft from residential)
30 feet above grade maximum
Full cut-off height (within 50 ft of residential)
15 feet above grade maximum
Storage-area (security) lighting range
0.5 to 10.0 foot-candles on pavement
Applies to
Nonresidential and multifamily development only
Civil penalty
Up to $500 per violation (Sec. 15.4.4)
Nonconforming cutoff date
Fixtures installed before June 12, 2000 exempt

Summary

Durham's Unified Development Ordinance caps directional and full cut-off security lighting at 30 feet above grade when the fixture sits 50 feet or more from a residential lot line, dropping to 15 feet within that buffer. Fixtures must be designed so no light escapes above a horizontal plane, and storage-area security lighting on nonresidential and multifamily sites is separately capped at 10.0 foot-candles on the pavement below.

C. Full-Cutoff Lighting

The maximum height for directional or full cut-off lighting fixtures (fixtures designed to ensure that no light is emitted above a horizontal line parallel to the ground) shall be:

Thirty feet above grade if located at least 50 feet from a residential property line; and

Fifteen feet above grade if located within 50 feet of a residential property line.

Full Breakdown

4 of Durham's UDO, jointly administered by Durham City-County Planning for both the city and the unincorporated county, sets the technical lighting standards, and Sec. C gives the shielding and height rule for directional and full cut-off fixtures: the category covering security lighting over storage areas, parking lots and building entrances. ' Where such a fixture sits at least 50 feet from a residential property line it may reach 30 feet above grade; within 50 feet of a residential line the cap drops to 15 feet.

Non-directional fixtures are capped at 15 feet regardless of distance and must be translucent or baffled. Under the companion foot-candle table in Sec. 0 foot-candles measured on the pavement. The rules apply to nonresidential and multifamily development under Sec. weekends) outside the UC, UC-2 and DD districts. Fixtures installed before June 12, 2000 may remain as nonconforming, but any replacement or expansion must meet the current standard.

Violations & Fines

Durham City-County Planning enforces Sec. 7.4.3 through the UDO's general enforcement article: after a notice of violation, the Planning Director or designee may issue a citation carrying a civil penalty of up to $500 per violation under Sec. 15.4.4, with unpaid penalties collectible as a civil debt. A continuing violation, an unshielded or oversized fixture left in place, can draw a separate daily penalty, and the city may condition or withhold other permits until the fixture is corrected.

Frequently Asked Questions

How tall can a security light be near my Durham property line?
Under UDO Sec. 7.4.3.C, a full cut-off security fixture can reach 30 feet above grade only if it sits at least 50 feet from a residential property line. Inside that 50-foot buffer the maximum height drops to 15 feet, and the fixture must be built so no light shines above a horizontal line parallel to the ground, the ordinance's technical definition of full cut-off.
Does Durham require shielded fixtures for storage-area or parking-lot security lighting?
Yes. Sec. 7.4.3.A sets a foot-candle range of 0.5 to 10.0 for storage-area security lighting measured on the pavement, and Sec. 7.4.3.C requires directional fixtures to be full cut-off so light is not emitted above the horizontal plane. Non-directional fixtures are capped at 15 feet and must be translucent or baffled to block the visible light source.
Do these lighting rules apply to a single-family home in Durham?
No. Sec. 7.4.2 limits mandatory lighting design standards to nonresidential and multifamily developments; single-family and two-family lots are not subject to the foot-candle table or the full cut-off height limits. Temporary event lighting and outdoor recreational lighting tied to a permitted event are also exempt if the fixtures sit at least 100 feet from any residential use.
What happens if a business in Durham installs an unshielded security light?
The Planning Director or designee can issue a notice of violation followed by a citation carrying a civil penalty of up to $500 under UDO Sec. 15.4.4. The penalty can be assessed again for each day the fixture stays out of compliance, and the city can withhold or condition other permits on the property until the lighting is corrected.

Sources & Official References

Other rules in Durham

All Durham rules

Compare Durham to another location·View the North Carolina outdoor lighting overview

Get notified when Light Trespass & Shielding in Durham, NC changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.