Sussex County, DE Parking Rules: Loading Zones (2026)
Key Facts
- Trigger
- New build or 25%+ floor-area increase
- Retail/warehouse: 2,000-10,000 sq ft
- 1 loading space
- Retail/warehouse: 40,000-60,000 sq ft
- 4 loading spaces
- Minimum space size
- 12 ft wide x 40 ft deep
- Funeral home space
- 1 berth per chapel
- Governing section
- Zoning Code § 115-167
Summary
Sussex County requires commercial buildings to provide dedicated off-street loading berths sized by floor area, from one space at 2,000 square feet up to four or more for large retail, warehouse or industrial buildings, under Zoning Code § 115-167.
Except as otherwise provided in this chapter, when any building or structure is hereafter erected or structurally altered to the extent of increasing the floor area by 25% or more or any building is hereafter converted for the uses listed in Column 1 of the chart below, when such buildings contain the floor areas specified in Column 2, accessory off-street loading spaces shall be provided as required in Column 3 or as required in subsequent sections of this article.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4401089; v17 updated 2025-06-17; through 06-17-2025).
Full Breakdown
Article XXIII of Chapter 115 governs off-street loading. Section 115-167 triggers the requirement whenever a building is erected, structurally altered to increase floor area by 25% or more, or converted to a listed use. Retail stores, department stores, restaurants, wholesale houses, warehouses and manufacturing or industrial establishments need one loading space between 2,000 and 10,000 square feet of floor area, scaling up to two spaces (10,000-20,000 sq ft), three spaces (20,000-40,000 sq ft), four spaces (40,000-60,000 sq ft), and one additional space for each 50,000 square feet above 60,000.
Apartment buildings, motels, hotels, offices, hospitals and similar institutions need one space between 5,000 and 25,000 square feet, two between 25,000 and 100,000, three between 100,000 and 200,000, and one additional per 100,000 square feet above that; funeral homes need one berth per chapel. Section 115-170A defines a loading space as a minimum 12-foot-wide, 40-foot-deep area within the building or on the same lot for standing, loading or unloading trucks (funeral homes may reduce that to 10 by 25 feet with 8-foot vertical clearance under § 115-170B).
Loading areas must be drained to eliminate standing water, surfaced with erosion-resistant material, and kept clean, per § 115-170C. Under § 115-168C, the Planning and Zoning Commission may modify a loading requirement it finds clearly excessive and unreasonable, and § 115-169 requires mixed-use buildings to provide loading as if the entire building were devoted to whichever listed use needs the most spaces.
Violations & Fines
Erecting, expanding by 25% or more, or converting a building to a listed use without providing the required off-street loading spaces under § 115-167, or building a loading space smaller than the 12-by-40-foot minimum under § 115-170A, violates Article XXIII. The Planning and Zoning Commission may withhold approval or, per § 115-168C, adjust a requirement it finds excessive, but noncompliant sites can be denied a certificate of occupancy.
Frequently Asked Questions
How many loading spaces does a commercial building need in Sussex County?
How big must an off-street loading space be in Sussex County?
Can Sussex County reduce a business's loading space requirement?
Sources & Official References
Other rules in Sussex County
Compare Sussex County to another location·View the Delaware parking rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.