Skip to main content
CityRuleLookup

Union County, NC Parking Rules: Loading Zones (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Office/hospital minimum
1 space per 25,000-100,000 sq ft, up to 3
Industrial/retail minimum
1 space per 15,000-50,000 sq ft, up to 4
Space size
10 ft x 30 ft, 14 ft vertical clearance
Semi-trailer size
12 ft x 55 ft loading space
Screening
S2 screen required within 50 ft of R district

Summary

Commercial and industrial buildings in unincorporated Union County must provide off-street loading spaces sized to the building's floor area, not just parking. Section 45.120 of the Unified Development Ordinance sets minimum loading-space counts by square footage and requires each space to be at least 10 feet wide and 30 feet long, or 12 by 55 feet for semi-tractor trailers.

These county ordinances apply to unincorporated areas of Union County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

Minimum Requirements Whenever the normal operation of any use involves regular delivery or shipment to or from the subject use, off-street loading area must be provided in accordance with this section to accommodate the delivery or shipment operations in a safe and convenient manner. ... Table 45-5: Loading Requirements for Office, Lodging and Hospital Uses Gross Floor Area [1] (sq. ft.) Minimum Loading Spaces Required 0–25,000 0 25,001–100,000 1 100,001–250,000 2 250,001 or more 3 ... Size Required off-street loading spaces must be at least 10 feet in width and 30 feet in length, exclusive of drive aisles. Spaces must have a minimum vertical clearance of at least 14 feet. When delivery or shipment regularly occurs by semi-tractor trailers, the loading space must be at least 12 feet in width and 55 feet in length.

Full Breakdown

120 requires any use in unincorporated Union County that involves regular delivery or shipment to provide off-street loading space sized to its building. For office, lodging and hospital uses, Table 45-5 sets the minimum count: no loading space is required below 25,000 square feet of gross floor area, one space from 25,001 to 100,000 square feet, two from 100,001 to 250,000 square feet, and three above that. Industrial, retail, wholesale, distribution and storage uses follow the steeper schedule of Table 45-6, needing one space once floor area passes 15,000 square feet, two past 50,000, three past 100,000 and four above 250,000 square feet.

Every required space must measure at least 10 feet wide and 30 feet long with 14 feet of vertical clearance, rising to 12 feet wide and 55 feet long where semi-tractor trailers regularly load. Loading areas must sit on the same lot as the use they serve, must let trucks maneuver to and from the public right-of-way without blocking it or a parking aisle, and an unenclosed loading area within 50 feet of a residentially zoned property needs S2-level screening on every side that abuts the R-zoned parcel. 060 that the permit-issuing authority weighs against traffic and neighborhood impacts before approving a reduced ratio.

Violations & Fines

Operating without the loading spaces Table 45-5 or 45-6 requires, or running an unscreened loading area within 50 feet of a residential district, violates Section 45.120 and triggers Article 95 enforcement: a 10-day warning citation, then $50, $200 and $500 fines for repeat citations, and a misdemeanor fine of up to $500 or 30 days under NCGS 14-4 for a use that stays noncompliant.

Frequently Asked Questions

How many loading spaces does a retail building need in unincorporated Union County?
Table 45-6 of Section 45.120 sets the minimum: none below 15,000 square feet of gross floor area, one from 15,001 to 50,000 square feet, two from 50,001 to 100,000, three from 100,001 to 250,000, and four above 250,000 square feet.
How big does a required loading space have to be?
Section 45.120 requires at least 10 feet of width and 30 feet of length with 14 feet of vertical clearance. Where semi-tractor trailers regularly make deliveries, the space must be at least 12 feet wide and 55 feet long instead.
Can a business get fewer loading spaces than the table requires?
Yes, through alternative compliance under Section 45.120. The applicant submits a loading study meeting Section 45.060's requirements showing the table's ratio does not match actual demand, and the permit-issuing authority can approve a reduced ratio if it will not hurt traffic circulation or neighborhood welfare.

Sources & Official References

Other rules in Union County

All Union County rules

Compare Union County to another location·View the North Carolina parking rules overview

Get notified when Loading Zones in Union County, NC changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.