Connecticut Statewide Rule

Connecticut Building Design Criteria for Homes

Some RestrictionsApplies statewide across Connecticut (2026)

Key Facts

Seismic design category
B, statewide
Weathering
Severe
Termite risk
Moderate-Heavy
Winter design temperature
7°F
Ice barrier underlayment
Required
Flood hazards
To be determined locally: the one item left to the municipality
Last verified: August 19, 2026

Summary

Connecticut fixes almost the entire residential design criteria table statewide: seismic category B, weathering Severe, a 7°F winter design temperature, required ice barrier underlayment and climate zone 5A.

(Amd) TABLE R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA — Seismic Design Category: B. Weathering: Severe. Termite: Moderate-Heavy. Winter Design Temp: 7°F. Ice Barrier Underlayment Required: YES. Flood Hazards: To be determined locally. Air Freezing Index: 1,500 or less. Mean Annual Temperature: 50°F. Climate Zone: 5A. Footnote a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code.

Full Breakdown

Most states leave the climatic and geographic design criteria for local officials to complete. Connecticut fills in nearly all of it centrally. The amended Table R301.2 sets the seismic design category at B, weathering at Severe, termite risk at Moderate-Heavy, the winter design temperature at 7°F, the air freezing index at 1,500 or less, the mean annual temperature at 50°F, and the climate zone at 5A, all statewide. Ice barrier underlayment is required. Flood hazards are the one item explicitly left local: the table reads simply that they are to be determined locally. A footnote adds that the Severe weathering classification may require a higher strength concrete or grade of masonry than the structural requirements alone would call for, which is a practical consequence worth catching at specification rather than at inspection.

Violations & Penalties

These criteria are enforced through plan review and inspection rather than as offences in themselves. Specifying concrete or masonry that meets only the structural requirement, and not the Severe weathering classification, is the common failure: the footnote exists precisely because that substitution looks compliant on a structural calculation and is not.

Frequently Asked Questions

What seismic design category applies in Connecticut?
Category B, and it is set statewide in the amended Table R301.2 rather than varying by town.
Why does the weathering classification matter?
A footnote in the code states that Severe weathering may require a higher strength concrete or grade of masonry than is needed to satisfy the structural requirements alone. Meeting the structural number is not by itself enough.
Is anything in the table left to my town?
Flood hazards. The table records them as to be determined locally, while every other criterion, seismic, weathering, termite, winter design temperature, ice barrier, is fixed statewide.