Indiana Statewide Rule
Indiana Building Design Criteria by County
Key Facts
- Wind speed
- 115 mph in all 92 counties
- Seismic design category
- A in 47 counties, B in 31, C in 14
- Weathering
- Severe statewide
- Termite risk
- Moderate to Heavy statewide
- Ice shield underlayment
- Required in every county
- Code edition enforced
- 2020 Indiana Residential Code, based on the 2018 International Residential Code
Summary
Indiana's state design criteria table gives every county a wind speed of 115 mph, a weathering classification of Severe and required ice shield underlayment, while seismic design category varies from A to C across the state.
TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA. Footnote a. Wind exposure shall be determined on a site-specific basis in accordance with SECTION R301.2.1.4. Footnote b. Seismic design category shall be assigned according to this TABLE or SECTION R301.2.2.1.1. Footnote c. Foundation is the minimum depth, in inches, from the finish grade to the bottom of the footing. Footnote d. The grade of masonry units shall be determined from ASTM C34, C55, C62, C73, C90, C129, C145, C216, or C652.
Full Breakdown
Beyond frost depth and snow load, Indiana's substituted Table R301.2(1) fixes the rest of the residential design criteria county by county. Wind speed is uniform: 115 mph in all 92 counties, with wind exposure determined on a site-specific basis under Section R301.2.1.4. Weathering is classified Severe and termite risk Moderate to Heavy throughout, and ice shield underlayment is required in every county. The value that varies most is the seismic design category: forty-seven counties are Category A, thirty-one are B, and fourteen are C, with the higher categories concentrated in the southwest of the state near the New Madrid seismic zone. Footnote b allows the category to be assigned either from the table or under Section R301.2.2.1.1. The table also carries an air freezing index and a mean annual temperature for each county, both of which matter chiefly when designing a frost-protected shallow foundation.
Violations & Penalties
These are design inputs enforced through plan review and inspection rather than offences in their own right. Drawings specifying assemblies below the stated criteria, a roof without the required ice shield underlayment, or a structure designed for a lower seismic category than its county carries, are corrected at review or flagged at inspection before work proceeds.
Frequently Asked Questions
What wind speed do Indiana homes have to be designed for?
Which Indiana counties have the highest seismic design category?
Is ice shield underlayment required in Indiana?
Sources
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.