Hemet, CA Water Use Rules: Recycled Water Rules (2026)
Key Facts
- Trigger
- Dual-plumbed or dual-sourced recycled water
- Requirement
- Approved backflow prevention assembly
- Testing cost
- Paid by the customer
- Enforcement
- City Cross-Connection & Backflow Control program
- Non-compliance
- Water service can be shut off
Summary
Hemet requires backflow protection on any property with a dual-plumbed or dual-sourced recycled water, non-potable water, or graywater system, plus cross-connection testing paid for by the customer.
Water service protection is required in, but not limited to conditions where:(1)Premises having an auxiliary water supply. (All wells that have not been properly abandoned or destroyed are considered an auxiliary water supply);(2)Premises having a booster pump that is located on a customer's potable water system;(3)Premises having chemicals or fertilizers that are applied by injection in the customer's domestic water system;(4)Premises that have a fire suppression system that uses: chemical additives or storage tanks;(5)Premises that have dual-plumbed or dual-sourced recycled water, non-potable water or graywater systems;(6)Premises where a commercial or residential business is being operated that may pose a contamination risk to the public potable water system;(7)Premises that have a remote service;(8)Premises that have looped potable service piping with more than one point of connection to the City of Hemet main distribution system. In this situation, backflow protection is required on both services.(9)Premises where cross-connections are likely to occur;(10)Premises where an owner denies access to the premises where there is no property for inspection by authorized city personnel;(11)Note: when a site is dual-plumbed or dual-sourced with recycled water, cross-connection testing will also be required, at the customer's expense;(12)Premises where there is a non-testable device. (Ord. No. 1983, § 2, 9-28-21)
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 69 Update 2).
Full Breakdown
Under the city's cross-connection and backflow control program, premises that are dual-plumbed or dual-sourced with recycled water, non-potable water, or graywater must install an approved backflow prevention assembly at the water service connection. Any site interconnected with recycled water also triggers ongoing cross-connection testing at the customer's expense. The City of Hemet Cross-Connection and Backflow Control program administers the requirement and can discontinue potable water service until the assembly is installed, tested, and maintained to the program's satisfaction.
Violations & Fines
Water service may be discontinued until a required backflow prevention assembly is installed, tested, and maintained; service is not restored until the deficiency is corrected to the Cross-Connection and Backflow Control program's satisfaction.
Frequently Asked Questions
Does Hemet require backflow protection for recycled water hookups?
Who enforces Hemet's recycled water backflow rules?
Sources & Official References
Other rules in Hemet
California rules heatmap·Compare Hemet to another location·View the California water use rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.