Key Facts

Requirement
Alarm required in every dwelling
Placement
Within 10 ft of bedrooms
Exception
Inside bedroom if fuel appliance present
Maintenance standard
NFPA 720
Replacement trigger
Inoperable or end-of-life signal
Adopted
Ord. No. 4466 §8, 4-18-2022

Summary

Rochester requires carbon monoxide alarms in every dwelling under Code section 7-8-48, incorporating Section 915.2 of the Minnesota Fire Code. Detection must sit outside each sleeping area within ten feet of the bedrooms, or inside the bedroom itself if a fuel-burning appliance is present. Alarms must be maintained under NFPA 720 and replaced once they go inoperative or start signaling end-of-life.

Carbon monoxide alarms shall be installed in dwellings in accordance with Section 915.2 of the Minnesota Fire Code: ... Carbon monoxide detection shall be installed in dwelling units outside of each separate area within ten feet of the bedrooms. Where a fuel-burning appliance is located in a bedroom or its attached bathroom, carbon monoxide detection shall be installed within the bedroom. ... Carbon monoxide alarms and carbon monoxide detection systems shall be maintained in accordance with NFPA 720. Carbon monoxide alarms and carbon monoxide detectors that become inoperable or begin producing end-of-life signals shall be replaced.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 8 Update 1).

Full Breakdown

The city's fire safety chapter folds carbon monoxide protection into the same ordinance that governs smoke alarms, adopted by Ordinance No. 4466, section 8, effective April 18, 2022. 2 of the Minnesota Fire Code. Section 7-8-49 places the detector outside each separate sleeping area, within ten feet of the bedrooms; if a fuel-burning appliance sits in the bedroom or its attached bathroom, the detector has to go inside the bedroom itself. Section 7-8-50 applies the same rule to sleeping units, though it allows the detector to sit outside the sleeping area within ten feet if the attached sleeping unit has no fuel-burning appliance and is not served by a fuel-burning forced-air furnace.

Section 7-8-51 covers upkeep: carbon monoxide alarms and detection systems must be maintained under NFPA 720, and any unit that becomes inoperable or starts giving an end-of-life signal has to be replaced, not left until the next inspection cycle. Because this sits inside the fire code, compliance is checked the same way as other fire-safety items: through rental registration inspections under chapter 7-9 for rental units, and through routine fire code enforcement for owner-occupied homes. There is no exemption for owner-occupied single-family houses; the "dwellings" language in section 7-8-48 is unqualified.

Violations & Fines

A missing or non-functioning carbon monoxide alarm is a fire code violation under section 8-2-18, enforced by the fire code official. For rental property, a failed carbon monoxide alarm found during a rental inspection is grounds for a notice of violation under section 7-9-9, and repeated deficiencies can support denial, suspension or revocation of the property's registration certificate under section 7-9-5.

Frequently Asked Questions

Does Rochester require carbon monoxide detectors in every home?
Yes. City Code section 7-8-48 requires carbon monoxide alarms in dwellings citywide, referencing Section 915.2 of the Minnesota Fire Code. The rule applies to owner-occupied houses and rental units alike, and rental units are checked for compliance during inspections conducted under chapter 7-9.
Where does the detector have to go?
Section 7-8-49 places it outside each separate sleeping area within ten feet of the bedrooms. If a fuel-burning appliance, like a gas furnace or water heater, sits in the bedroom or its attached bathroom, the detector must be installed inside that bedroom instead.
How often does a carbon monoxide alarm need to be replaced?
Section 7-8-51 requires maintenance under NFPA 720 and replacement once an alarm becomes inoperable or starts producing an end-of-life signal. Unlike smoke alarms, which section 7-8-47 caps at ten years from manufacture, the code does not set a fixed age limit for CO alarms.
Who enforces the carbon monoxide alarm rule?
The fire code official enforces it under section 8-2-18 as a fire code violation. For registered rental property, a missing or dead carbon monoxide alarm found during inspection triggers a notice of violation under section 7-9-9 and can affect the property's rental registration certificate.

Sources & Official References

Other rules in Rochester

All Rochester rules

Compare Rochester to another location·View the Minnesota building safety overview

Get notified when Carbon Monoxide Detectors in Rochester, MN changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.