Greenburgh, NY Building Safety: Door Locking Hardware (2026)
Key Facts
- Required hardware
- Panic hardware on all fire exits
- Other locking devices
- Prohibited on fire exits, any time
- Minimum exits
- Two, placed as far apart as possible
- Battery lighting (50+ occupancy)
- At least 30 minutes duration
- Governing chapter
- Ch. 330, Cabaret Law firesafety rules
- General violation penalty
- Up to $250 and/or 15 days jail
Summary
Greenburgh Code § 330-13(L) requires every fire exit in a licensed cabaret to have panic hardware, and bars any other locking device on those exits at any time. The rule sits inside the Cabaret Law's firesafety requirements, which also mandate a minimum of two well-separated exits and smoke and heat detection.
L. All fire exits in all cabarets are required to have panic hardware. No other locking device shall be permitted on fire exits at any time.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4570580; v39 updated 2025-10-22; through 10-22-2025).
Full Breakdown
Chapter 330's Cabaret Law imposes building-occupancy and firesafety standards on any licensed cabaret in Greenburgh. Section 330-13(L) is direct: "All fire exits in all cabarets are required to have panic hardware. " This sits alongside § 330-13(J), which requires a minimum of two exits placed as far apart from each other as reasonably possible, and § 330-13(C), which requires sufficient exterior lighting at all fire exits for safe egress. Section 330-13(B) adds that cabarets with a permitted occupancy of 50 or more people must have auxiliary rechargeable battery lighting lasting at least 30 minutes, positioned so tables, chairs or fixtures cannot block it, with the Bureau of Fire Prevention setting the number and placement.
Section 330-13(I) caps maximum occupancy per National Fire Prevention Association Code No. 101 or stricter State Department of Labor rules, with the Fire Marshal posting the occupancy limit in a conspicuous location. Section 330-13(M) separately requires smoke and heat detectors in storage rooms, attics, basements, kitchens and boiler rooms, wired since January 10, 1983 to sound an alarm automatically, with an annual compliance affidavit due to the Fire Prevention Bureau every January 1. All of these requirements apply on top of, not instead of, the New York State Building Construction Code under § 330-13(D).
Violations & Fines
Failing to install or maintain required panic hardware, or the broader firesafety requirements of § 330-13, is enforceable as a Cabaret Law violation under § 330-18(B): a fine of up to $250 and/or 15 days' imprisonment. The Fire Marshal, Building Inspector or police may also order immediate evacuation and license suspension under § 330-17 where the condition threatens public safety.
Frequently Asked Questions
Can a Greenburgh nightclub keep its fire exits padlocked during business hours?
Does this panic hardware rule apply to every business in Greenburgh?
What else does Greenburgh's Cabaret Law require for fire safety?
Sources & Official References
Other rules in Greenburgh
New York rules heatmap·Compare Greenburgh to another location·View the New York building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Door Locking Hardware in Nearby Cities
How other cities in Westchester County handle door locking hardware.