Carrollton, TX Building Safety: Elevator Maintenance (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Governing standard
ASME A17.1
Certificate requirement
Current inspection cert posted/on file
Inspection interval
Per ASME A17.1, Appendix N
Passenger elevator uptime
At least 1 running while occupied
Single-elevator exception
Temporary outage for testing/servicing
Appeal window
30 days to Property Standards Board

Summary

Carrollton's Commercial Property Maintenance Code requires every elevator, escalator, and dumbwaiter to be kept in compliance with ASME A17.1, with a current inspection certificate posted or on file, and at least one elevator running whenever an occupied building has passenger elevators.

(E) Elevators, escalators and dumbwaiters. (1) Elevators, dumbwaiters and escalators shall be maintained in compliance with ASME A17.1. The most current certification of inspection shall be on display at all times within the elevator or attached to the escalator or dumbwaiter, or the certificate shall be available for public inspection in the office of the building operator. The inspection and test shall be performed at not less than the periodical intervals listed in ASME A17.1, Appendix N, except where otherwise specified by the authority having jurisdiction. (2) In buildings equipped with passenger elevators, at least one elevator shall be maintained in operation at all times when the building is occupied. (Exception: Buildings equipped with only one elevator shall be permitted to have the elevator temporarily out of service for testing or servicing.)

Full Breakdown

Carrollton Code of Ordinances Section 98.06(E), part of the Commercial Property Maintenance Code's mechanical and electrical requirements in Chapter 98, requires elevators, dumbwaiters, and escalators to be maintained in compliance with ASME A17.1, the national safety code for elevators and escalators. The most current certification of inspection must be on display at all times within the elevator, attached to the escalator or dumbwaiter, or available for public inspection in the building operator's office. Inspections and tests must be performed at not less than the periodic intervals listed in ASME A17.1, Appendix N, unless the authority having jurisdiction specifies otherwise.

Section 98.06(E)(2) adds an operational-availability rule for buildings equipped with passenger elevators: at least one elevator must be maintained in operation at all times the building is occupied, with a narrow exception letting a single-elevator building take that elevator temporarily out of service for testing or servicing. This mechanical-systems mandate sits inside the same chapter's broader owner-responsibility scheme: Section 98.05 covers plumbing and drainage, Section 98.07 covers fire safety and means of egress, and Section 98.08 makes the property owner liable for Chapter 98 violations even when a manager or occupant is actually responsible for the premises, unless the ordinance says otherwise.

An owner or occupant affected by a DCO decision, notice, or order under Chapter 98 can appeal to the Property Standards Board within 30 days under Section 98.09(A), and the Board can adopt, modify, or reverse the DCO's decision by majority vote under Section 98.09(D).

Violations & Fines

A person may not occupy, as owner-occupant, or permit another to occupy, any premises with elevators, escalators, or dumbwaiters that are not maintained under ASME A17.1, per Section 98.06(A). The owner remains liable for the violation under Section 98.08 regardless of any delegation to a manager, and the owner or occupant has a 30-day window to file a written appeal to the Property Standards Board under Section 98.09(A) before further enforcement.

Frequently Asked Questions

What maintenance standard applies to elevators in Carrollton commercial buildings?
Section 98.06(E) of the Commercial Property Maintenance Code requires elevators, dumbwaiters, and escalators to be maintained in compliance with ASME A17.1, with the current inspection certificate posted in the elevator or available in the building operator's office.
Does an occupied Carrollton building need to keep an elevator running at all times?
Yes, if it has passenger elevators. Section 98.06(E)(2) requires at least one elevator to remain in operation whenever the building is occupied, except a building with only one elevator may take it temporarily out of service for testing or servicing.
Who is responsible if a Carrollton building's elevator isn't properly maintained?
The property owner. Section 98.08 holds the owner liable for Chapter 98 violations even if a manager or occupant is actually responsible for the premises, unless the ordinance specifically states otherwise, and Section 98.09(A) gives an affected party 30 days to appeal a DCO order to the Property Standards Board.

Sources & Official References

Other rules in Carrollton

All Carrollton rules

Texas rules heatmap·Compare Carrollton to another location·View the Texas building safety overview

Get notified when Elevator Maintenance in Carrollton, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.