Skip to main content
CityRuleLookup

Grove City, OH Building Safety: Elevator Maintenance (2026)

Heavy Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

State Law
ORC Chapter 4105
Inspection
Annual by state
Standard
ASME A17.1
Residential
SFH generally exempt
Penalty
Up to 1,000 per day

Summary

Elevators in Grove City commercial and multi-family buildings are regulated by the Ohio Department of Commerce Division of Industrial Compliance under ORC Chapter 4105. Annual inspections and operating permits are mandatory.

Section 4105.10 Frequency of inspection. (A) Except as provided in division (B) of this section, elevators shall be inspected in accordance with the following: (1) Every passenger elevator, escalator, moving walk, and freight elevator, including gravity elevators, shall be inspected twice every twelve months. (2) Power dumb-waiters, hoists, and other lifting or lowering apparatus, not designed to carry persons, permanently installed, either on or between rails or guides, shall be inspected at least once every twelve months. (3) The board of building standards may designate, by rule, classifications of passenger elevators with a capacity of seven hundred fifty pounds or less that shall be inspected once every twelve months. (B) Division (A) of this section does not apply to an elevator installed in a private residence. Section 4105.15 Certificate of operation - renewal. No certificate of operation for any elevator shall be issued by the director of commerce until such elevator has been inspected as required by this chapter. Certificates of operation shall be renewed by the owner or user of the elevator in accordance with rules adopted by the superintendent of industrial compliance pursuant to section 4105.12 of the Revised Code. Section 4105.30 Testing performed by licensed personnel. (A) It shall be the responsibility of the owner of all conveyances to have an elevator contractor licensed under Chapter 4785. of the Revised Code ensure that the required tests are performed at intervals in compliance with the ASME A17.1/CSA B44 Appendix N and ASCE 21. All tests shall be performed by an elevator mechanic licensed under Chapter 4785. of the Revised Code.

Source: ORC Chapter 4105View official code

Full Breakdown

ORC 4105.17 and OAC 4101:5 require annual inspection of passenger and freight elevators by state-licensed inspectors. Operating certificates must be posted in each elevator cab. Maintenance must be performed by licensed elevator contractors under ASME A17.1 Safety Code for Elevators and Escalators. Private residential elevators in single-family homes are generally exempt from state inspection but must meet installation code. Violations can result in red-tag shutdowns until repairs and re-inspection. Grove City Building Division coordinates with state inspectors during new construction commissioning.

Violations & Fines

Operating expired certificate: civil penalties up to 1,000 dollars per day under ORC 4105.20. Operating red-tagged elevator: criminal misdemeanor charges and liability for injuries.

Sources & Official References

Other rules in Grove City

All Grove City rules

Compare Grove City to another location·View the Ohio building safety overview

Get notified when Elevator Maintenance in Grove City, OH changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Elevator Maintenance in Nearby Cities

How other cities in Franklin County handle elevator maintenance.

Dublin, OH
Heavy Restrictions
Westerville, OH
Heavy Restrictions
Columbus, OH
Heavy Restrictions