Key Facts
- Trigger 1
- Built as a short-term rental (UDC 23.08.220(c))
- Trigger 2
- >3,600 sq ft that can't meet NFPA 1142 flow
- Applies to
- New 1- and 2-family homes, townhouses
- Design standard
- IRC Appendix U
- Residential credit
- 50% flow reduction, NFPA 13D/P2904
- Commercial credit
- 75% flow reduction, NFPA 13/13R
Summary
New one- and two-family homes and townhouses in unincorporated Grant County need an automatic fire sprinkler system under Grant County Code § 14.04.030(1)(j) whenever the home will operate as a short-term rental or tops 3,600 square feet without enough fire flow to meet NFPA 1142.
(j)AV107.1 Fire Sprinklers.An approved automatic fire sprinkler system shall be installed in new one-family and two-family dwellings and townhouses in accordance with appendix U when any one of the following applies:1.The residential dwelling is proposed to be constructed as a Hospitality Commercial Establishments—Transient Residence per the Unified Development Code Section 23.08.220(c);2.The residential dwelling exceeds 3,600 square feet of covered area and cannot meet fire flow requirements per NFPA 1142. ... (a)Required fire flow shall be determined using National Fire Protection Association (NFPA) 1142 and/or the Wildland Urban Interface Code for all commercial structures and residential structures exceeding three thousand six hundred square feet.(b)The installation of a fire sprinkler system, NFPA 13D or P2904 System, shall reduce the fire flow requirement by fifty percent for residential development, where applicable.
Full Breakdown
030(1)(j), requires an approved automatic fire sprinkler system built to International Residential Code Appendix U in any new one-family or two-family dwelling or townhouse that meets either of two triggers. 010 imposes on that same use. The second is size and water supply: a dwelling over 3,600 square feet of covered area that cannot meet the fire flow required by NFPA 1142 must sprinkler instead of relying on hydrant flow alone. 010 sets the underlying fire flow standard using NFPA 1142 or the Wildland Urban Interface Code, and then builds in the incentive to sprinkler: installing an NFPA 13D or P2904 residential system cuts the required fire flow by fifty percent, while a commercial NFPA 13 or NFPA 13R system cuts it by seventy-five percent, letting a project with limited water supply or hydrant spacing proceed where it otherwise could not.
040's precedence rule applies if any adopted code conflicts: the first-named code in the list governs. Grant County Development Services keeps the adopted codes on file for public review and administers the sprinkler and fire-flow review as part of ordinary building permitting in the unincorporated area.
Violations & Fines
Building a new one- or two-family home or townhouse without the required sprinkler system when either trigger applies, transient-residence use or a 3,600-square-foot home that can't meet NFPA 1142 fire flow, blocks final building permit sign-off and certificate of occupancy from Development Services, and a transient residence built without it cannot get its GCC 15.03.010 fire marshal operational permit either.
Frequently Asked Questions
Does every new house in unincorporated Grant County need a fire sprinkler system?
Why would a big house need sprinklers instead of just more water flow?
If I turn my house into an Airbnb, does the sprinkler rule apply even if it's small?
What standard governs how the sprinkler system is installed?
Sources & Official References
Other rules in Grant County
Compare Grant County to another location·View the Washington building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.