Skip to main content
CityRuleLookup

Grant County, WA Parking Rules: Loading Zones (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing section
UDO § 23.12.140
Size trigger
10,000+ sq ft of gross floor area
Minimum space
10 ft wide, 30 ft long, 14'6" clearance
Residential buffer
Screening/noise control within 100 feet
Mitigation tools
Barriers, berms, walls, or hour restrictions

Summary

Grant County requires one off-street loading space for any non-residential building of 10,000 square feet or more, with a 10-by-30-foot minimum size, and mandates noise mitigation when a loading space sits within 100 feet of residential property.

These county ordinances apply to unincorporated areas of Grant County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

23.12.140 - Off-street Loading Requirements (a)Every non-residential building used for retail, wholesale, manufacturing, or storage activities, excluding self-service storage facilities, shall provide off-street loading spaces in accordance with the standards listed below:(1)One (1) loading space shall be required for each building containing ten thousand (10,000) or more square feet of gross floor area.(2)Each loading space shall be a minimum of ten (10) feet wide, thirty (30) feet long, have an unobstructed vertical clearance of fourteen (14) feet six (6) inches, and be surfaced, improved, and maintained as required by this section. ... All loading space areas shall be separated from required parking areas and shall be designated as truck loading spaces.(3)Any loading space located within one hundred (100) feet of areas designated for residential use shall be screened and operated as necessary to reduce noise and visual impacts. Noise mitigation measures may include architectural or structural barriers, berms, walls, or restriction on the hours of operations.

Full Breakdown

140, Off-street Loading Requirements, governs commercial and industrial loading in unincorporated Grant County. Subsection (a) applies the rule to every non-residential building used for retail, wholesale, manufacturing, or storage, explicitly excluding self-service storage facilities, and (1) triggers the requirement at a size threshold: one loading space is required for each building with 10,000 square feet or more of gross floor area. Subsection (2) sets the physical dimensions: a minimum of 10 feet wide by 30 feet long, with an unobstructed vertical clearance of 14 feet 6 inches, surfaced and maintained, and it requires loading areas to be kept separate from required parking and clearly designated as truck loading spaces.

The residential-protection piece is subsection (3): any loading space located within 100 feet of areas designated for residential use must be screened and operated to reduce noise and visual impacts, and the code lists specific mitigation tools, architectural or structural barriers, berms, walls, or a restriction on hours of operation, that the county can require rather than leaving the choice open-ended. Subsection (4) extends the screening duty to dumpsters as well, requiring loading areas and dumpsters to be screened from public streets and pedestrian connections with walls, trellises, arcades, or landscaping, so the loading-and-servicing side of a commercial building stays out of view from the street even where it is not adjacent to housing.

Violations & Fines

A qualifying non-residential building that lacks the required loading space, uses an undersized space, or operates a loading space within 100 feet of residential use without the screening or noise mitigation required by § 23.12.140(3), is out of compliance and subject to correction through Grant County Development Services' building permit and code enforcement process before or after occupancy.

Frequently Asked Questions

When does a Grant County business need an off-street loading space?
UDO § 23.12.140(a)(1) requires one off-street loading space for any non-residential retail, wholesale, manufacturing, or storage building with 10,000 square feet or more of gross floor area, excluding self-service storage facilities.
How big must a loading space be under county code?
Section 23.12.140(a)(2) sets a minimum of 10 feet wide by 30 feet long with an unobstructed vertical clearance of 14 feet 6 inches, and the space must be surfaced, maintained, and kept separate from required parking.
Are there hours restrictions on loading near homes in Grant County?
Section 23.12.140(a)(3) requires screening and noise mitigation, which can include a restriction on hours of operation, for any loading space located within 100 feet of land designated for residential use.

Sources & Official References

Other rules in Grant County

All Grant County rules

Compare Grant County to another location·View the Washington parking rules overview