Multnomah County, OR Building Safety: Fire Sprinkler Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Standard secondary zone
100 feet minimum
Sprinkler trigger
reduced zone under 50 feet
System required
central-station monitored 13D sprinklers
50-100 ft alternative
central-station monitored alarm system
Fence buffer
no combustible fence within 12 feet
Governing section
MCC § 39.4155(B)

Summary

In unincorporated Multnomah County's farm and forest zones, the standard secondary fire safety zone around a dwelling is 100 feet. A landowner can shrink that buffer under MCC 39.4155, but if the reduced zone drops below 50 feet the dwelling must carry a central-station monitored 13D fire sprinkler system.

City-specific rules exist: Portland, and Gresham have their own fire sprinkler requirements rules that differ from Multnomah County's county-level regulations. If you live in one of those cities, check the city-specific page instead.

(B) Exceptions to secondary fire safety zones shall only be granted upon satisfaction of the following standards: ... (2) If the proposed secondary fire safety zone is less than fifty feet, the dwelling or structure shall be constructed in accordance with the International Fire Code Institute Urban-Wildland Interface Code Section 504 Class 1 Ignition Resistant Construction as adopted August, 1996, or as later amended, and ... (5) A dwelling shall have a central station monitored 13D sprinkler system if the secondary fire safety zone equivalents of subsection (B) (2) above are utilized. Expansions of existing single family dwellings as allowed by MCC 39.4075 (A) shall not be required to meet this standard, but shall satisfy the standard of MCC 39.4115(C)(3) and (E).

Full Breakdown

4115(A) requires every new dwelling in the county's Exclusive Farm Use and Commercial Forest Use base zones to maintain a primary fire safety zone of at least 30 feet and a secondary fire safety zone of at least 100 feet around the structure. 4155(A). Approval turns on the construction and equipment standards in subsection (B): if the reduced zone still falls between 50 and 100 feet, the dwelling must meet International Fire Code Institute Urban-Wildland Interface Code Section 505 Class 2 Ignition Resistant Construction, and combustible fences are barred within 12 feet of the structure.

Push the reduced zone below 50 feet, and the stricter Section 504 Class 1 construction applies, plus a mandatory central-station monitored NFPA 13D residential fire sprinkler system under subsection (B)(5). A reduced zone of 50 to 100 feet instead triggers a central-station monitored fire alarm system under (B)(4), a lighter alternative to sprinklers. 4115(C)(3) and (E). Multnomah County's Land Use Planning Division reviews each exception as part of the dwelling's zoning approval, and the local Rural Fire Protection District is the resource named in the code for verifying defensible-space compliance.

Violations & Fines

Occupying a dwelling that accepted a reduced secondary fire safety zone without installing the required 13D sprinkler or alarm system voids the MCC 39.4155 exception; Multnomah County Land Use Planning can require a retrofit or revoke the approval, and occupancy sign-off can be withheld until the monitored system is installed and active. Combustible fencing placed within the 12-foot buffer around the dwelling is a separate standards violation subject to correction under the same exception review.

Frequently Asked Questions

Does every home in unincorporated Multnomah County need fire sprinklers?
No. Only dwellings granted an exception that reduces the secondary fire safety zone below 50 feet under MCC 39.4155(B) must install a central-station monitored 13D sprinkler system. Homes that keep the full 100-foot secondary zone required by MCC 39.4115(A) are not subject to this sprinkler mandate.
What is a secondary fire safety zone?
It is a wildfire fuel-reduction buffer extending at least 100 feet beyond the 30-foot primary fire safety zone around a dwelling in the county's farm and forest zones, per MCC 39.4115(A). Vegetation must be thinned and spaced so fire cannot spread between tree crowns.
What happens if I expand my existing house instead of building new?
Expansions allowed under MCC 39.4075(A) are exempt from the 13D sprinkler standard. They must instead meet the accessory/expansion development standards at MCC 39.4115(C)(3) and (E), which cover setback and site-specific fire safety zone requirements for additions rather than new construction.
Who reviews a reduced fire safety zone exception?
Multnomah County's Land Use Planning Division processes the MCC 39.4155 exception as part of the dwelling's zoning approval, weighing lot width, road proximity, and clustering with existing structures before approving the reduced buffer and its construction and sprinkler or alarm conditions.

Sources & Official References

Other rules in Multnomah County

All Multnomah County rules

Compare Multnomah County to another location·View the Oregon building safety overview

Get notified when Fire Sprinkler Requirements in Multnomah County, OR changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Fire Sprinkler Requirements in Cities Across Multnomah County