Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Applies to
Group R-3 residential
Triggered by
Framing & roofing complete
Certifier
MD-licensed surveyor or engineer
Gate
No close-in until approved

Summary

Rockville withholds close-in inspections on Group R-3 homes until a Maryland-licensed surveyor or engineer certifies the framed building height, submitted right after framing and roofing finish.

110.3.4.1 Residential Building Height. The height of residential buildings in Group R-3 shall conform with Chapter 25, Zoning Ordinance, Section 25.10.05 of the Rockville City Code. A building height certification shall be submitted to the City of Rockville after all framing and roofing is complete. No close-in inspections will be performed until the certification has been approved by the City. The building height certification shall be prepared and signed by a licensed land surveyor in the State of Maryland, a civil engineer licensed in the State of Maryland or any individual who is deemed qualified by the Building Official.

Exception:

(1)Residential buildings in Group R-3 where the proposed addition, alteration or reconstruction does not exceed or increase the height of the existing structure. New SFD construction shall be excluded. Sections 111.1.1, 111.1.2, and 111.1.3 are added to the IBC to read as follows:

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 17 Update 1).

Full Breakdown

IBC § 110.3.4.1, added locally at City Code § 5-87, requires a building height certification for residential (Group R-3) construction once framing and roofing are done. No close-in inspection, the step that covers up rough framing, electrical, plumbing, and mechanical work behind drywall, proceeds until the City has approved that certification. The certification must be prepared and signed by a Maryland-licensed land surveyor, a Maryland-licensed civil engineer, or another individual the Building Official deems qualified. The rule exempts additions or alterations that don't raise an existing structure's height, but applies to all new single-family detached construction.

Violations & Fines

Proceeding to close-in inspection or covering framing before the required height certification is approved violates § 5-87 (IBC § 110.3.4.1) and halts the inspection process until corrected.

Frequently Asked Questions

When is a building height certification required in Rockville?
For Group R-3 residential construction, submitted to the City after framing and roofing are complete, per § 5-87 (IBC § 110.3.4.1).
Can close-in inspection happen before the certification is approved?
No, § 110.3.4.1 blocks close-in inspections until the City has approved the height certification.

Sources & Official References

Other rules in Rockville

All Rockville rules

Compare Rockville to another location·View the Maryland building safety overview

Get notified when Building Inspections in Rockville, MD changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.