Clayton County, GA Building Safety: Plumbing Permits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Washing machine pan drain
Minimum 1 inch, IPC §415.3.1
Sewage lift station tank
1,000 gal concrete / 500 gal fiberglass
Lift station setback
At least 10 feet from residence
Pump size
Minimum 1/2 HP grinder type
Kitchen faucet flow cap
1.8 gpm at 60 psi
Water closet flow cap
1.28 gallons per flush
Minimum plumbing permit fee
$50.00 (§18-47(d)(4))

Summary

Clayton County adopts the International Plumbing Code with local amendments under Section 18-71, adding requirements the base code doesn't cover: a catch pan under every washing machine that could leak, and a single-family sewage lift station, minimum 1,000-gallon tank, wherever a home's building drain sits lower than the sewer tap.

These county ordinances apply to unincorporated areas of Clayton County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

Local amendments submitted to the state department of community affairs for review, which are adopted by reference thereto and incorporated as part of the this Code for Clayton County, Georgia... Section 415.3. Required Pans. Where washing machines are installed in locations where leakage of the washing machine or connections will cause damage, the washing machine shall be installed in a pan approved for such use. ... Section 712.5. Single Family Sewage Lift Station. In the event that in any residence the building drain is lower than the sewer taps, a single family sewage lift station shall be required.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 104).

Full Breakdown

Clayton County Code § 18-71 adopts the International Plumbing Code with local amendments that were 'submitted to the state department of community affairs for review' before being incorporated into Chapter 18. 1 setting that drain size. 5, requiring a single-family sewage lift station whenever a residence's building drain sits lower than the sewer taps: the tank must hold at least 1,000 gallons if concrete or 500 gallons if fiberglass and sit no closer than 10 feet to the residence, the incoming sewer line must be at least 4 inches with a clean-out at the building drain connection, the outflow line at least 2 inches with a check valve at the pump, the pump at least a half-horsepower grinder type, and the system needs a dedicated electrical circuit with a high-level float switch tied to an audible alarm inside the dwelling. The 2025 amendment (Ord. No. 28 gallons per flush. 25 per-fixture charge for residential replacement fixtures under § 18-47(d)(4).

Violations & Fines

Plumbing work done without the required permit, or that does not meet these adopted amendments, is subject to the general Code penalty of up to $1,000.00 or six months imprisonment under § 1-12 unless a more specific penalty applies, and the county official can issue a stop-work order under § 18-33 or revoke the permit under § 18-34 for work that violates the construction codes.

Frequently Asked Questions

Does Clayton County require a special sewage lift station for homes?
Yes, when the building drain sits lower than the sewer taps. Section 18-71(a)(2) requires a single-family sewage lift station with a tank of at least 1,000 gallons (concrete) or 500 gallons (fiberglass), set at least 10 feet from the residence, with a minimum half-horsepower grinder pump and a dedicated circuit tied to an audible high-level alarm inside the home.
Do washing machines need a drip pan under Clayton County's plumbing code?
Yes, wherever a leak could damage the surrounding area. Section 415.3, added by Section 18-71(a)(1), requires the washing machine to sit in an approved pan with at least a 1-inch drain that runs to a waste receptor or floor drain, or extends outside and terminates 6 to 24 inches above the ground.
What flow rates apply to faucets and toilets installed in Clayton County?
The county's 2025 amendment to Section 604.4 caps kitchen faucets at 1.8 gallons per minute, private lavatory faucets at 1.2 gpm, showerheads at 2.0 gpm, and water closets at 1.28 gallons per flush, applying these limits to every plumbing system, including one- and two-family dwellings.

Sources & Official References

Other rules in Clayton County

All Clayton County rules

Compare Clayton County to another location·View the Georgia building safety overview

Get notified when Plumbing Permits in Clayton County, GA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.