Skip to main content
CityRuleLookup

Taylor, TX Building Safety: Plumbing Permits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Adopted code
2018 International Plumbing Code
Local name
Plumbing Code of the City of Taylor
Permit applicant must be
Texas-licensed master plumber
Exemption
homestead owner under state law
Min. sewer depth
12 inches below grade
Vent pipe height
6 in. roof / 7 ft. deck
Fee refund deadline
180 days from payment

Summary

Taylor has adopted the 2018 International Plumbing Code, with local amendments, as Chapter 22 of its Code of Ordinances. Anyone applying for a plumbing permit must be a Texas-licensed master plumber or exempt under state law, such as a homeowner working on their own homestead, and a licensed plumber must register with the city before starting work.

[There is hereby adopted by the city the International Plumbing Code, 2018 Edition, except the changes and amendments hereafter set out which is for the public safety, health, and general welfare of the city and its citizens.] ... (a)The International Plumbing Code, 2018 edition, and Appendices B, C, D, and E thereto as published by the International Code Council, Inc. are hereby adopted and made a part of this chapter, except as amended below. ... 106.3.4 Permits; licensing.(a)A person applying for a plumbing permit shall be:(1)A State of Texas licensed master plumber; or(2)Exempt under state law from the licensing requirement.(b)If applicable, a state licensed master plumber shall register with the City in accordance with the City's registration policy and shall show proof of the license before any work is performed within the City.

Full Breakdown

Sec. 22-1 adopts the International Plumbing Code, 2018 Edition, "for the public safety, health, and general welfare of the city and its citizens," and Sec. 22-2 amends it in several respects. 4, added by the same amendment, requires anyone applying for a plumbing permit to be a State of Texas licensed master plumber or otherwise exempt from licensing under state law; a licensed master plumber must register with the city under its registration policy and show proof of license before performing any work in the city, and a homestead owner claiming the state-law exemption must prove to the building official that the residence is the owner's own homestead.

3 lets the code official refund fees paid in error if the original permittee applies in writing within 180 days of payment. 1 requires roof vent pipes to terminate at least six inches above a normal roof, or at least seven feet above a roof used as a deck, promenade, or sunbathing area.

Violations & Fines

Performing plumbing work without a valid permit, without proof of the required master-plumber license, or without proving a claimed homestead exemption under amended Subsection 106.3.4 violates Chapter 22 and is enforced by the city's building official, who can refuse to issue or finalize a permit for noncompliant work. Fee refunds for amounts paid in error are available only if the original permittee applies in writing within 180 days of payment, under amended Subsection 106.6.3.

Frequently Asked Questions

Can I do my own plumbing work in Taylor?
Yes, if the property is your homestead. Amended Subsection 106.3.4 exempts a residential owner from the master-plumber licensing requirement, but you must show the building official proof that you own the home as your homestead before starting work.
Which plumbing code does Taylor enforce?
The city adopted the International Plumbing Code, 2018 Edition, under Sec. 22-1, renamed locally the "Plumbing Code of the City of Taylor, Texas," along with Appendices B, C, D, and E and the local amendments in Sec. 22-2.
How deep must a building sewer be buried?
Amended Subsection 305.4.1 requires building sewers connecting to a private sewage disposal system to be installed at least 12 inches below finished grade at the septic tank connection, and building sewers generally must sit at least 12 inches below grade.
How high must a plumbing vent pipe extend above the roof?
Amended Subsection 903.1 requires open vent pipes to terminate at least six inches above the roof, or at least seven feet above the roof if the roof is used as a deck, promenade, sunbathing area, or other assembly space.

Sources & Official References

Other rules in Taylor

All Taylor rules

Texas rules heatmap·Compare Taylor to another location·View the Texas building safety overview

Get notified when Plumbing Permits in Taylor, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Plumbing Permits in Nearby Cities

How other cities in Williamson County handle plumbing permits.

Cedar Park, TX
Some Restrictions