Key Facts

Standard residential cap
38 feet (R-1 through R-4, RU-1, RU-1A, RU-2)
R-5/R-5A multi-family cap
4 stories, not a foot limit
Commercial districts
No fixed max height (B-3, B-4, B-5, B-6)
Setback trade-off over 35 ft
+1 ft side/rear setback per 2 ft of height
Height review over 35 ft
Fire department must approve ladder access
General violation penalty
Up to $200 fine or 30 days jail (Sec. 1-13)

Summary

Unincorporated Florence County caps building height at 38 feet in its standard single-family districts, R-1 through R-4, and RU-1, RU-1A and RU-2, under Table III. The R-5 and R-5A multi-family districts allow up to four stories, and commercial buildings over 35 feet need fire department sign-off on ladder access.

These county ordinances apply to unincorporated areas of Florence County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

Sec. 30-30. - Table III: Zoning setbacks. District ... Max Hgt.

(ft) (c) ... R-1 15,000 30,000 100 25 10 50 30 60 38 40 0.25 ... R-5 6,000 12,000 50 25 5 25 20 40 4 stories 70 0.30 ... R-5A 6,000 12,000 50 25 5 25 20 40 4 stories 70 0.30 ... (e) There is no maximum: provided side and rear setbacks shall increase by one foot for each two feet in height over 35 feet for buildings outside of the B-4 district; further provided that approval of buildings over 35 feet shall be based on fire ladder capabilities as determined by the fire department with jurisdiction.

Full Breakdown

Florence County's Table III, Sec. ' The standard single-family districts, R-1 through R-4, along with the rural RU-1, RU-1A and RU-2 districts, all cap height at 38 feet. The R-5 and R-5A multi-family districts break from that number entirely: instead of a foot limit, Table III caps them at four stories. Commercial and industrial districts, B-3, B-4, B-5 and B-6, carry no fixed maximum height at all, marked '(e)' in the table, but Note (e) attaches two conditions: side and rear setbacks must increase by one foot for every two feet of height over 35 feet for any building outside the B-4 district, and any building proposed over 35 feet needs its fire ladder capabilities approved by the fire department with jurisdiction before it can be built.

In effect, a commercial building in B-3, B-5 or B-6 that wants to go taller than 35 feet has to widen its side and rear yards proportionally and clear a fire-access review; B-4, the county's downtown district built lot-line to lot-line, is exempted from the escalating setback requirement even though it shares the same uncapped height allowance.

Violations & Fines

Exceeding the applicable height cap, 38 feet in R-1 through R-4 and the RU districts, or four stories in R-5 and R-5A, without a variance is a zoning violation subject to Florence County's general Code penalty, Sec. 1-13: a fine of up to $200.00, up to 30 days' imprisonment, or both, with each day the oversized structure remains treated as a separate offense. A commercial building over 35 feet built without the required fire-ladder approval from the fire department is a separate violation of Note (e).

Frequently Asked Questions

How tall can I build a house in unincorporated Florence County?
Up to 38 feet in the standard single-family districts, R-1 through R-4, and in the rural RU-1, RU-1A and RU-2 districts. Sec. 30-30's Table III sets that as the Max Hgt. figure, measured from the average finished grade at the front of the structure.
What's the height limit in the R-5 multi-family district?
Four stories rather than a set number of feet. Table III breaks from the 38-foot standard used in R-1 through R-4 and caps the R-5 and R-5A multi-family districts at four stories instead, reflecting their higher intended density and building form.
Is there a height limit for commercial buildings?
Not a fixed one. B-3, B-4, B-5 and B-6 carry no maximum height under Table III, but Note (e) requires side and rear setbacks to grow by one foot for every two feet over 35 feet outside B-4, and any building over 35 feet needs the fire department's sign-off on ladder access.

Sources & Official References

Other rules in Florence County

All Florence County rules

Compare Florence County to another location·View the South Carolina building setbacks & zoning overview

Get notified when Structure Height Limits in Florence County, SC changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.