Skip to main content
CityRuleLookup

Prince George's County, MD Building Setbacks & Zoning: Structure Height Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Principal structure height max
40 feet
Accessory structure height max
15 feet
Height measured from
street grade to roofline
Terrace add-on allowance
up to 5 feet
Exempt features
chimneys, antennas, mechanical equipment
Enforcing agency
DPIE
Variance authority
Board of Zoning Appeals, § 27-3613

Summary

Prince George's County limits principal structures in the RSF-65 zone, its standard single-family subdivision zone, to 40 feet under Section 27-4202(e); detached accessory buildings such as garages and sheds are capped at 15 feet. Height is measured from street grade to the roofline, and a short list of features, like chimneys and antennas, are exempt from the cap under Section 27-2202.

These county ordinances apply to unincorporated areas of Prince George's County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

Principal structure height, max. (ft) | 40 | 40 Accessory structure height, max. (ft) (3) | 15 | 15

... Building Height The vertical distance between an approved "street" grade at a point at the middle of the front of the "building" to either: The highest point of roof surface of a flat roof; The deck line of a mansard roof; or The average height between the eaves and ridge of a gable, hip, or gambrel roof. ... Except within the MIO Zone, the maximum structure height limits established in PART 27-4: Zones and Zone Regulations, shall not apply to ... Monuments, water towers, silos, granaries, barns, utility transmission towers, derricks, cooling towers, fire towers, and other similar structures not intended for human occupancy.

Full Breakdown

Section 27-4202(e)'s Intensity and Dimensional Standards table caps the principal structure height in the RSF-65 (Residential, Single-Family-65) zone at 40 feet, applying equally to a single-family detached dwelling and to any other principal use permitted on the lot. A footnote to the same table separately limits detached accessory structures, such as a garage, shed, or workshop, to 15 feet. Section 27-2201 defines exactly how that height is measured: the vertical distance between an approved street grade at a point at the middle of the front of the building and either the highest point of a flat roof, the deck line of a mansard roof, or the average height between the eaves and ridge of a gable, hip, or gambrel roof.

If a building sits on a terrace, the terrace can add up to 5 feet before it counts against the cap, and if the building is set back 35 feet or more from the street line, height is instead measured from the average finished ground elevation along the front-facing side. Section 27-2202 then exempts a defined list of features from the 40-foot cap entirely: monuments, water towers, silos, barns, and utility towers not intended for human occupancy, plus rooftop elements like spires, chimneys, elevator shaft enclosures, and mechanical equipment, so long as they cover no more than 25 percent of the roof and extend no more than 25 percent above the height limit.

Roof-mounted antennas, satellite dishes, and small-scale solar or wind systems are likewise exempt if they meet the use-specific standards in Sections 27-5203(b)(13) and (16). A homeowner who wants to exceed 40 feet for a habitable structure, rather than an exempt feature, must obtain a dimensional variance from the Board of Zoning Appeals under Section 27-3613 by demonstrating unnecessary hardship.

Violations & Fines

Constructing a principal structure taller than the RSF-65 zone's 40-foot cap, or an accessory building over 15 feet, without an approved variance violates Section 27-8206. DPIE can issue a civil fine under Subtitle 28 or pursue misdemeanor prosecution carrying up to a $500 fine and 90 days in jail; a continuing height violation is treated as a new offense each day it remains uncorrected.

Frequently Asked Questions

How tall can a house be in PG County's RSF-65 zone?
Section 27-4202(e) caps the principal structure height at 40 feet in the RSF-65 zone. Height is measured under Section 27-2201 from the street grade at the middle of the building's front to the highest point of a flat roof, or the average eave-to-ridge height on a pitched roof.
What's the height limit for a detached garage or shed?
A footnote to the RSF-65 dimensional table caps detached accessory structures at 15 feet, well below the 40-foot principal structure limit, regardless of whether the accessory building sits at the rear or side of the lot.
Are chimneys or antennas exempt from the height cap?
Yes. Section 27-2202 exempts spires, chimneys, elevator shaft enclosures, mechanical equipment, and similar rooftop features from the 40-foot cap if they cover no more than 25 percent of the roof and rise no more than 25 percent above the limit. Roof-mounted antennas and small-scale solar systems are exempt too, if they meet the use-specific standards.
Can I build taller than 40 feet with approval?
Only through a dimensional variance. Section 27-3613 lets the Board of Zoning Appeals approve a height variance in the RSF-65 zone if strict application of the 40-foot cap would create an unnecessary hardship on the property.

Sources & Official References

Other rules in Prince George's County

All Prince George's County rules

Compare Prince George's County to another location·View the Maryland building setbacks & zoning overview

Get notified when Structure Height Limits in Prince George's County, MD changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.