Skip to main content

Issaquah, WA Building Setbacks & Zoning: Structure Height Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified November 2026

Key Facts

Governing section
Issaquah Land Use Code § 18.404.050
Height measured to
Midpoint of highest gable, or coping of a flat roof
Roof pitch
Minimum 4:12 and maximum 12:12 for pitched roofs
Gabled dormers
No more than 50 percent of total roof area in plan view
Average grade method
Spot elevations every 10 feet around the footprint
Additional height tiers
Up to 50 feet and up to 65 feet by Director deviation
Residential zone limits
Table 18.404.090(A)

Summary

Issaquah measures building height under Land Use Code § 18.404.050 from the lower of existing or finished average grade to the midpoint of the highest gable on a 4:12 to 12:12 pitched roof, or to the coping of a flat roof. Water towers, chimneys to code minimums, elevator shafts and similar features are exempt.

1. Nonshoreline Areas. Building or structure height must be measured from the average grade of the existing or finished grade, whichever is lower, to the midpoint of the highest gable of a pitched or hipped roof with a minimum 4:12 pitch and a maximum of 12:12 pitch, or the highest point of the coping of a flat roof (see Figures 18.404.050(B)(1) and 18.404.050(D)(1)). All parts of the roof extending above the base building height must be a minimum 4:12 pitch unless specifically excepted in subsection C of this section. Gabled dormers may comprise no more than 50 percent of the total roof area as measured in plan view. No portion of a shed roof may extend above the base building height limit. An architectural feature may not be used to measure or establish building height. ... C. Height Exemptions. The following uses and features are not subject to height limitations and do not require a deviation, provided they are architecturally integrated. ... 3. Chimneys and smoke stacks to the minimum required by the Building Code;

Full Breakdown

Land Use Code § 18.404.050 states its purpose as balancing lot size, building bulk and open space, and ensuring that architectural character and scale are compatible with the surrounding area. In nonshoreline areas, height is measured from the average grade of the existing or finished grade, whichever is lower, to the midpoint of the highest gable of a pitched or hipped roof with a minimum 4:12 pitch and a maximum of 12:12 pitch, or to the highest point of the coping of a flat roof. All parts of the roof extending above the base building height must be at least 4:12 pitch unless an exemption applies. Gabled dormers can make up no more than 50 percent of the total roof area in plan view, no portion of a shed roof can extend above the base building height limit, and an architectural feature cannot be used to measure or establish building height. In shoreline areas, height is measured from the average of the existing topography of the portion of the lot under the building or structure.

Average grade comes from an accurate scaled drawing of the footprint showing existing and proposed topography with contour lines at two-foot intervals. Spot elevations are taken at points every 10 feet around the footprint, using the lower of existing or proposed, and the elevations are added up and divided by the number of points.

Certain features are not subject to height limitations and need no deviation, provided they are architecturally integrated: water towers, power transmission towers, chimneys and smoke stacks to the minimum required by the Building Code, flag poles within the limits of Chapter 18.612 IMC, scenery lofts and flytowers, mechanical penthouses, rooftop equipment screening and stair towers to the Building Code minimum, elevator shafts to the minimum required by IMC Title 16, and solar panels or arrays per IMC 18.602.060. Wireless communication towers follow Chapter 18.512 IMC, except towers regulated in residential zoning districts.

The base and maximum height for each residential zone are set in Table 18.404.090(A), Residential Zones Form and Intensity Standards. Section 18.404.060 allows more height on parcels outside Central Issaquah, Issaquah Highlands and Talus, including Multifamily-Medium and Multifamily-High parcels. Up to 50 feet through a Director's deviation requires stepbacks that reduce the gross floor area of each added story by 25 percent of the story beneath it, a 10 percent increase in pervious surface, and, next to a lower-density residential zone, the lower zone's maximum base height for the first 30 feet from the property line. Up to 65 feet adds clusters of trees around the buildings and an approved site development permit. Neither tier can exceed the maximum building height in Table 18.404.100(B).

Violations & Fines

Section 18.404.050 prints no penalty of its own. Height above the zone's base building height needs an approved deviation under § 18.404.060 or § 18.404.080, and a proposal that fails the deviation conditions can apply for a variance under Chapter 18.210 IMC. The § 18.404.050(C) exemptions apply only to the listed uses and features, and only when they are architecturally integrated.

Frequently Asked Questions

How is building height measured in Issaquah?
Outside shoreline areas, height is measured from the average grade of the existing or finished grade, whichever is lower, to the midpoint of the highest gable of a pitched or hipped roof, or to the highest point of the coping of a flat roof. Shoreline areas use the average of the existing topography under the building.
What roof pitch does Issaquah require above the base height?
All parts of the roof extending above the base building height must be a minimum 4:12 pitch unless specifically excepted. The pitched roof measurement assumes a minimum 4:12 and a maximum 12:12 pitch. Gabled dormers can make up no more than 50 percent of the total roof area in plan view, and shed roofs cannot rise above the base limit.
Which features can exceed the height limit in Issaquah?
Water towers, power transmission towers, chimneys and smoke stacks to the Building Code minimum, flag poles, scenery lofts and flytowers, mechanical penthouses and stair towers to the Building Code minimum, elevator shafts, and solar panels or arrays are exempt, provided they are architecturally integrated, under § 18.404.050(C).
Where are the height limits for each residential zone?
Section 18.404.090 holds Table 18.404.090(A), Residential Zones Form and Intensity Standards, which lists base and maximum building height by zone. Olde Town properties also fall under Chapter 18.700 IMC, and parcels seeking more than the base height can apply for the Director's deviation described in § 18.404.060.

Sources & Official References

Other rules in Issaquah

All Issaquah rules

Compare Issaquah to another location·View the Washington building setbacks & zoning overview

Get notified when Structure Height Limits in Issaquah, WA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Structure Height Limits in Nearby Cities

How other cities in King County handle structure height limits.

Auburn, WA
Some Restrictions
Federal Way, WA
Some Restrictions
Kent, WA
Some Restrictions
Kirkland, WA
Some Restrictions
Renton, WA
Some Restrictions
Seattle, WA
Some Restrictions