Skip to main content
CityRuleLookup

Midwest City, OK Building Setbacks & Zoning: Structure Height Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Standard cap
35 feet in most single-family districts
Higher-density cap
Up to 45 feet in denser districts
Height bonus
1 extra setback foot per foot over 45'
Minor projections
May exceed limit by 15 feet
Governing table
Zoning Ordinance § 3.2, Table 3.2-1

Summary

Midwest City caps residential building height at 35 feet in most single-family zoning districts, with several higher-density districts allowed up to 45 feet under the city's Zoning Ordinance area-regulations table.

Maximum Building Height (Exceptions listed in Section 4.6) 35' 35' 35' 35' 35' 35' 35' 35' 45' 45' 45' 45' 45' 45' 45' 45', additional height shall be permitted on a ratio of one additional foot of building setback for every foot of building height above forty-five (45)'. 35' 35' Minimum Front Setback 30' 30' 25' 25' 25' 25' 25' 25' 25' 25' 25' 25' 25' 25' 25' 25' 20' 20' Minimum Side Setback

• Adjacent to Lot; 30' 15' 10' 10' 7' 7' 7' 7' 7' 7' 7' 7' 7' 7' 7' 7' 7' 7'

• Adjacent to Street; 15' 15' 15' 15' 15' 15' 15' 15' 15' 15' 15' 15' 15' 15' 15' 15' 15' 15'

• May have one (1) zero side setback for unattached dwellings per section 4.7 No No No Yes Yes Yes Yes N/A Yes Not Applicable Not Applicable Not Applicable Yes Not Applicable Not Applicable Not Applicable Yes Yes

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 21).

Full Breakdown

Midwest City's Zoning Ordinance (Appendix A to the Code of Ordinances) sets maximum building height by residential zoning district in Table 3.2-1, Residential Area Regulations and Standards Chart. The city's lower-density single-family districts, A-1, R-35, R-22, R-10, R-8, and R-6, cap height at 35 feet, matching the manufactured-home districts R-MH-1 and R-MH-2. Several higher-density multifamily and townhouse districts allow up to 45 feet, with one additional foot of building setback required for every foot of height above 45 feet. Chimneys, elevators, spires, and similar unoccupied projections may exceed the district limit by up to 15 feet without City Council approval under § 5.4.1.

Violations & Fines

Violating the Zoning Ordinance's height limit is a municipal offense punishable by a fine up to $100 plus costs per § 7.10.1; each day the violation continues is a separate offense.

Frequently Asked Questions

How tall can a house be in Midwest City?
Most residential districts, including R-6, R-8, R-10, R-22, R-35 and A-1, cap building height at 35 feet under Table 3.2-1 of the city's Zoning Ordinance.
Can a building exceed 35 feet?
Yes, in several higher-density residential districts the limit rises to 45 feet, with one extra foot of building setback required for every foot of height above 45 feet.
Do chimneys or antennas count toward the height limit?
Chimneys, elevators, spires, and similar unoccupied projections may exceed the district's height limit by up to 15 feet without City Council approval, per § 5.4.1.

Sources & Official References

Other rules in Midwest City

All Midwest City rules

Compare Midwest City to another location·View the Oklahoma building setbacks & zoning overview

Get notified when Structure Height Limits in Midwest City, OK changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Structure Height Limits in Nearby Cities

How other cities in this county handle structure height limits.

Edmond, OK
Some Restrictions
Oklahoma City, OK
Some Restrictions