West Palm Beach, FL Building Setbacks & Zoning: Structure Height Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

SF3/SF5/SF7 max height
30 feet
SF11 max height
30 feet
MF20/MF32 max height
greater of 40 ft or 2ft/1ft setback
Rooftop equipment/chimney exemption
+10% over district limit
FAA flight-pattern limits
still apply, per Sec. 94-306(b)
Max fine, Sec. 94-9
$500 per day

Summary

West Palm Beach caps single-family homes at 30 feet in the SF3, SF5, SF7, SF11 and SF14 districts, per Sec. 94-72(a)(4). Multifamily MF20 and MF32 districts get a formula instead: the greater of 40 feet or two feet of height for every foot of side and rear setback provided. Sec. 94-306 lets rooftop equipment, chimneys and steeples exceed the limit by ten percent.

4. Maximum building height: 30 feet.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 76).

Full Breakdown

Sec. 94-72(a)(4) sets a flat 30-foot maximum building height for the SF3, SF5 and SF7 single-family districts, and sections 94-73(b)(3) and 94-74(a)(6) apply the same 30-foot cap to the SF11 small-lot district and the SF14 high-density single-family district. Multifamily zoning uses a different formula: Sec. 94-76 (MF20) and Sec. 94-77 (MF32) both cap building height at "the greater of 40 feet or two feet in height for each one foot in setback from side and rear lot lines," so a taller building is allowed only if it is pulled back further from its side and rear property lines. MF14 (Sec. 94-75(a)(3)) holds to the flat 30-foot limit like the single-family districts.

Sec. 94-306 carves out exemptions from every district's height cap: heating, ventilation and air-conditioning equipment, church steeples, bell towers, flagpoles, chimneys, parapets, stair enclosures, tanks, elevator hoistways, and television or radio antennas may exceed the applicable district height limit by ten percent. Even with that exemption, no structure, including exempt equipment, may exceed height limits set by the Federal Aviation Administration within a designated flight approach pattern, as filed with the city's planning and zoning administrator, per Sec. 94-306(b). Height is not the only ceiling on a structure's bulk: Sec. 94-80(b)(3) separately limits wall height at the side setback in the city's historic contextual districts to as little as 13 feet, rising one foot for each additional foot of side setback provided beyond the minimum.

Violations & Fines

Constructing a structure above its district's height limit, or above the ten-percent exemption allowed for rooftop equipment and architectural features, violates Chapter 94 under Sec. 94-9: a fine up to $500.00, with each day of continued violation treated as a separate offense, applies to the owner, tenant, builder, contractor or agent responsible. The city may also seek a court order to enjoin construction or compel removal of the excess height.

Frequently Asked Questions

How tall can a single-family house be built in West Palm Beach?
Up to 30 feet in the SF3, SF5, SF7, SF11 and SF14 districts, per Sec. 94-72(a)(4) and its counterparts in sections 94-73 and 94-74. The limit is measured to the building's overall height, not counting the rooftop exemptions in Sec. 94-306.
Do multifamily buildings get a taller height allowance?
Yes. MF20 and MF32 buildings under sections 94-76 and 94-77 may rise to the greater of 40 feet or two feet of height for every foot the building is set back from its side and rear lot lines, rewarding larger setbacks with additional height.
Can rooftop air-conditioning units or a chimney exceed the height limit?
Yes, within limits. Sec. 94-306(a) allows HVAC equipment, chimneys, steeples, flagpoles, tanks, elevator hoistways and antennas to exceed the applicable district's height cap by up to ten percent without a variance.
Does an airport flight path override the city's height limits?
It can. Sec. 94-306(b) bars any structure, including exempt rooftop equipment, from exceeding height limits set by the Federal Aviation Administration within a designated flight approach pattern on file with the planning and zoning administrator.

Sources & Official References

Other rules in West Palm Beach

All West Palm Beach rules

Florida rules heatmap·Compare West Palm Beach to another location·View the Florida building setbacks & zoning overview

Get notified when Structure Height Limits in West Palm Beach, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Structure Height Limits in Nearby Cities

How other cities in Palm Beach County handle structure height limits.

Boca Raton, FL
Some Restrictions