Skip to main content
CityRuleLookup

Outdoor Lighting in Brooklyn Park, MN (2026)

3 verified outdoor lighting rules for Brooklyn Park, Minnesota, sourced directly from the municipal code and official government pages.

Verified from official government sources

Dark Sky Rules

Brooklyn Park's zoning code caps outdoor light fixtures at 15 feet within 250 feet of any residential-zoned property and 25 feet beyond that distance, and every free-standing luminaire must have a cut-off angle of 90 degrees or less so light is directed downward. Low-pressure sodium fixtures are restricted to single-family, duplex and townhouse developments. The standards apply to all new development citywide.

Brooklyn Park Outdoor Lighting Shielding Rules

Some Restrictions

Brooklyn Park City Code § 152.1014(C)

§ 152.1014 LIGHTING STANDARDS. ... (B) Applicability. ... The following standards shall apply to all new development. Seasonal lighting is not regulated by this section. (C) Standards. ... (4) Free-standing luminaire regulations. Height maximums, as measured from the average elevation of the finished grade within ten feet of the structure or fixture to the highest point of the luminaire (includ...

Light Trespass & Shielding

Brooklyn Park requires every outdoor light source to be shielded so it cannot be seen from off the property, capping the maximum intensity at the side or interior property line at 0.5 foot-candles under the zoning code's glare standards. Flickering or flashing lights are barred except for public safety uses, and canopy lighting must sit flush with a flat lens.

Brooklyn Park Light Trespass and Glare Rules

Some Restrictions

Brooklyn Park City Code § 152.1014(D)

(D) Glare. All lighting must be arranged so as not to produce glare. All properties must be in compliance with the following: (1) All light sources must be controlled and equipped with lenses, louvers, shields, or prismatic control devices designed to prevent off-site views of the light source. (2) No flickering or flashing lights except those associated with public safety activities may be per...

Billboard Lighting

Billboards in the City of Brooklyn Park's I General Industrial District must have any illumination shielded so the light stays confined to the sign face, the same shielding standard the code applies to every illuminated sign in the city.

Brooklyn Park Billboard Sign Lighting Rule

Some Restrictions

Brooklyn Park City Code §§ 150.03, 150.29(F)(5)

ILLUMINATED SIGN. Any sign which is designed to be and/or is lighted by an artificial light source either directed upon it or illuminated from an interior source. All illuminated signs must have light sources shielded to confine direct illumination to the face area of the sign. ... (5) Sign illumination. Billboard sign illumination must meet the requirements of § 150.03 of this chapter.