Skip to main content
CityRuleLookup

Building Setbacks & Zoning in Collierville, TN (2026)

3 verified building setbacks & zoning rules for Collierville, Tennessee, sourced directly from the municipal code and official government pages.

Verified from official government sources

Setback Rules

Collierville sets residential yard setbacks district by district in § 151.027(A). R-1 requires 40 ft. in front, 30 ft. in the rear and 25 ft. total on the sides with neither side under 10 ft.; R-2 requires 30 ft. front, 30 ft. rear and 20 ft. total on the sides with neither under 7.5 ft.

Collierville TN Residential Yard Setbacks by Zoning District

Some Restrictions

Collierville Code of Ordinances § 151.027(A)

(A) Residential zoning districts. ... Zone Minimum Minimum Maximum District Description Lot Size Lot Width Height Setbacks [5] [2] ... Single- 15,000 sq. Front [1][3]: 40 ft. R-1 Low Density family ft. 100 ft. 35 ft. Rear: 30 ft. detached Side: 25 ft. total, neither side less than 10 ft. ... Medium Single- 11,250 sq. Front [1][3]: 30 ft. R-2 Density family ft. 90 ft. 35 ft. Rear: 30 ft. detache...

Structure Height Limits

Every residential zoning district in the Town of Collierville, Tennessee, carries a Maximum Height of 35 ft. in the § 151.027(A) table. Height is measured at the front wall or other portion of a building facing the street, and § 151.005(D) exempts items such as chimneys, spires and water towers from the cap.

Collierville TN Residential Building Height Limit: 35 Feet

Some Restrictions

Collierville Code of Ordinances § 151.027(A)

Maximum Height [2] ... R-1 Low Density 35 ft. ... [2] Maximum building height, as defined by § 151.003 measured at the front wall or other portion of a building facing the street; however, this limitation shall not apply to structures identified in § 151.005(D).

Lot Coverage Limits

Collierville prints a Maximum Lot Coverage figure only for its industrial districts: the RI Restrictive Industrial and GI General Industrial districts in § 151.027(C) are each capped at 50% of total lot area. The residential and commercial tables in the Town of Collierville use other controls instead.

Collierville TN Maximum Lot Coverage in Industrial Districts

Some Restrictions

Collierville Code of Ordinances § 151.027(C)

(C) Industrial zoning districts. Maximum Zone Area/ Maximum Floor Maximu m District Description Lot Height Area Lot Setbacks [4] Size [2] Ratio Coverage (FAR) Least No 50% of Front [1]:40 ft. RI Restrictive objectionable minimum 60 ft. None total Rear: 30 ft. adjoining residential [3], otherwise 25 ft. Industrial characteristics lot specified lot area Side: 25 ft. size General Well segregated N...

Looking for Shelby County county-wide rules?

County ordinances apply to unincorporated areas and may supplement Collierville city rules.

Building Setbacks & Zoning in Shelby County →