Setback Rules
Hampton's one-family districts require a 30-foot front setback, side yards totaling 25% of lot width, and a 20-foot rear yard that grows on deep lots.
Hampton Yard Setback Minimums
Some RestrictionsHampton Zoning Ordinance § 4-85 (R-9 District)
(1)Front yard. The front yard setback shall be a minimum of thirty (30) feet... (2)Side yard. The depth of the two (2) side yards shall total at least twenty-five (25) percent of the lot width, measured at the front setback line... (3)Rear yard. The rear yard setback shall be a minimum of twenty (20) feet, provided if the depth of the lot is greater than seventy-five (75) feet, the required dep...
Structure Height Limits
Hampton caps one- and two-family homes at 35 feet, with a bump to 45 feet only if both side yards run at least 25 feet deep.
Hampton Residential Height Limit
Some RestrictionsHampton Zoning Ordinance § 4-82 (R-9 District)
Buildings shall be a maximum of thirty-five (35) feet in height; provided that the height limit for any building may be increased to not more than forty-five (45) feet when side yards of not less than twenty-five (25) feet each are provided.
Lot Coverage Limits
In Hampton's townhouse and multifamily districts, buildings may cover no more than 20% of the lot, with 40% of the lot required to stay green area.
Hampton Townhouse Lot Coverage Limit
Some RestrictionsHampton Zoning Ordinance § 5-18
Buildings and structures, exclusive of physical recreational amenities, shall be permitted a total lot coverage of twenty (20) percent. A minimum of forty (40) percent of the total lot area shall be maintained as green area. This green area shall be exclusive of the eight (8) foot front and twenty (20) foot rear yards within fee-simple lots.