San Angelo's zoning ordinance sets minimum yards by district. RS-1 and RS-2 single-family lots require a 25-foot front yard, 5-foot side yards on each side, and a 20-foot rear yard (Zoning Ordinance Sec. 501.A).
San Angelo Building Setback Requirements
Some RestrictionsSan Angelo, TX, Code of Ordinances ch. 12, Exhibit A, Zoning Ordinance, Sec. 501.A
Except as specifically provided elsewhere in this Zoning Ordinance, dwelling height and building density shall be not more than, and yards and lot size shall not be less than are specified in the Table below for the type of use in the district in which such use is located.
Structure Height Limits
San Angelo caps residential structures at 35 feet or 2½ stories in every single-family and low-rise multifamily district, from R&E and RS-1 through RM-1, under Zoning Ordinance Sec. 501.A.
San Angelo Building Height Limits
Some RestrictionsLot Coverage Limits
San Angelo controls building intensity through a Maximum Floor Area Ratio, not a percent lot-coverage cap. RS-1 lots allow FAR 0.40, RS-2 0.50, and RS-3 0.60 under Zoning Ordinance Sec. 501.A.