Key Facts

Section
UCC 6.11.060, Defensible Space
Grass limit (0-30 ft)
5 inches maximum
Grass limit (30-50 ft)
18 inches maximum
Tree pruning
6 ft above ground within 50 ft
Review step
Written notice + site plan to Fire Marshal
Disposal rule
Open burning of cleared brush prohibited

Summary

In unincorporated Utah County's Wildland/Urban Interface zone, Utah County Code § 6.11.060 sets exact defensible-space clearances: grass kept under 5 inches within 30 feet of a structure, trees pruned and spaced, and all dead vegetation removed within 50 feet, with the Fire Marshal reviewing a site plan before construction begins.

City-specific rules exist: Eagle Mountain, and Provo have their own defensible space rules that differ from Utah County's county-level regulations. If you live in one of those cities, check the city-specific page instead.

Minimum Requirements: Unless otherwise specified by the Fire Marshal, minimum vegetation clearance will be as follows: Grass and Groundcovers: Dry or non-fire resistive grass and groundcovers shall be cleared and maintained to a maximum of five (5) inches in height within thirty (30) feet of the structure and a maximum of eighteen (18) inches in height from thirty (30) to fifty (50) feet from the structure. Areas beyond fifty (50) feet from the structure shall be determined by the fire marshal. Trees within fifty (50) feet of a structure shall be pruned to a height of six (6) feet above the ground, trees less than twenty (20) feet in height shall have the lower one-fourth (1/4) pruned. All trees within fifty (50) feet of a structure shall be kept free of dead or dying materials. Dead Vegetative Material: All dead vegetative material shall be removed and maintained clear within fifty (50) feet of any structure.

Full Breakdown

' The section then sets numeric clearance zones. Grass and groundcovers must be 'cleared and maintained to a maximum of five (5) inches in height within thirty (30) feet of the structure and a maximum of eighteen (18) inches in height from thirty (30) to fifty (50) feet from the structure'; beyond 50 feet the Fire Marshal sets the standard case by case. Trees within 50 feet of a structure must keep canopies at least 10 feet apart, may not extend within 10 feet of eaves, decks, balconies or chimney openings, and must be 'pruned to a height of six (6) feet above the ground,' with trees under 20 feet tall having their lower quarter pruned.

060 separately sets a 3-foot clearance around fire hydrants and a vegetation standard around propane and fuel tanks (a distinct provision covered on its own page). 090. Because defensible space is verified at the site-plan stage, a property that lets clearance lapse after occupancy can be cited on a routine Fire Marshal inspection, not just at initial construction.

Violations & Fines

Failing to maintain the § 6.11.060 clearances is a Fire Code violation. UCC § 6.06.070 classifies violating any provision of the fire chapter as a class B misdemeanor, carrying up to a $1,000 fine and six months in jail under § 1.04.010, with each day the hazard continues counted as a separate offense; open-burning cleared brush is a separate violation of § 6.11.060's disposal rule.

Frequently Asked Questions

How short does my grass have to be near my house?
Within 30 feet of a structure, dry grass and groundcovers must stay at 5 inches or less; from 30 to 50 feet the limit rises to 18 inches, per § 6.11.060. Beyond 50 feet, the Fire Marshal sets the requirement case by case.
Can I burn the brush I clear?
No. Section 6.11.060 requires disposal 'including chipping, burying, or removal to an approved landfill' completed before your building permit's final inspection, and it states plainly that 'open burning of these materials is prohibited' anywhere in the Wildland/Urban Interface area.
When does the Fire Marshal review my vegetation clearance?
Before construction starts. Section 6.11.060 requires written notice and a site plan submitted to the Utah County Fire Marshal 'before development or construction of any structure commences so that vegetation can be evaluated and ample clearance...can be determined.'
How close can tree branches be to my roof?
Not within 10 feet. Section 6.11.060 bars tree canopies from extending 'within ten (10) feet from under eaves, decks, or balconies or chimney openings,' and requires canopies of separate trees to stay at least 10 feet apart from each other.

Sources & Official References

Other rules in Utah County

All Utah County rules

Compare Utah County to another location·View the Utah environmental rules overview

Get notified when Defensible Space in Utah County, UT changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Defensible Space in Cities Across Utah County