Skip to main content
CityRuleLookup

Converse, TX Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Standard
Lowest floor at or above BFE
Applies to
New construction & substantial improvements
Certification
PE, architect, or surveyor required
Penalty
Up to $500 per violation
Citation
Sec. 22-82, Converse Code of Ordinances

Summary

Converse requires new and substantially improved residential structures to elevate the lowest floor to or above the base flood elevation, certified by a registered engineer, architect, or surveyor under Sec. 22-82.

New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated to or above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in division 4, subsection 22-63(a)(1), is satisfied.

Full Breakdown

In Converse's mapped special flood hazard areas, Sec. 22-82 sets the elevation standard for new construction and substantial improvements. Residential structures must have the lowest floor, including any basement, elevated to or above the base flood elevation (BFE) shown on the FIRM, with certification from a licensed engineer, architect, or surveyor filed with the floodplain administrator. Nonresidential buildings get an alternative: dry floodproof below the BFE with impermeable, hydrostatically-rated walls, engineer-certified. The code doesn't add a local freeboard cushion above BFE, it tracks the FEMA minimum directly.

Violations & Fines

Constructing below the required base flood elevation or without a floodplain development permit is a misdemeanor: up to $500 per violation plus costs under Sec. 22-102, and the city can pursue further legal action.

Frequently Asked Questions

Does Converse require freeboard above the base flood elevation?
No. Sec. 22-82 only requires the lowest floor at or above the BFE itself: there's no added local freeboard buffer beyond the FEMA minimum.
What happens if I build below the required elevation?
It's a misdemeanor under Sec. 22-102, punishable by up to $500 per violation plus costs, and the floodplain administrator can withhold permits or approvals.

Sources & Official References

Other rules in Converse

All Converse rules

Texas rules heatmap·Compare Converse to another location·View the Texas environmental rules overview

Get notified when Flood Elevation Requirements in Converse, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Bexar County handle flood elevation requirements.

San Antonio, TX
Some Restrictions