Skip to main content
CityRuleLookup

Weber County, UT Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Elevation standard
1 ft above base flood elevation
Certifier
PE, architect, or land surveyor
Flood vent ratio
1 sq in per sq ft enclosed area
Crawlspace height cap
4 feet below floor joist
Manufactured homes
Elevated to/above base flood elevation
RV exemption
On site under 180 consecutive days

Summary

New homes and substantially improved residential structures in Weber County's mapped flood hazard areas must have their lowest floor, including any basement, built at least one foot above the base flood elevation. A registered engineer, architect, or land surveyor has to certify the as-built elevation to the Floodplain Administrator before the structure is signed off.

These county ordinances apply to unincorporated areas of Weber County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

Sec 22-5-2 Specific Standards ... Residential Construction: New construction and substantial improvement of any residential structure shall have the lowest floor (including basement) elevated to one foot above the base flood elevation. If a freeboard option is noted, new construction and substantial improvement shall have the lowest floor (including basement) elevated to the freeboard elevation. A registered professional engineer, architect, or land surveyor shall submit certified elevations to the Floodplain Administrator that the standards of this Title are satisfied.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: ?).

Full Breakdown

Section 22-5-2's residential construction standard sets the elevation floor for the whole title: new construction and substantial improvement of a residential structure must have the lowest floor, including any basement, elevated to one foot above the base flood elevation, or to a higher noted freeboard elevation if the county has adopted a freeboard option for that area. Nonresidential buildings get an alternative: elevate to the same one-foot standard or design the structure to be watertight and able to resist hydrostatic and hydrodynamic loads below the base flood elevation, certified by a licensed engineer or architect.

Enclosed areas below the lowest floor used for parking, access, or storage must equalize floodwater pressure through flood vents totaling at least one square inch of opening per square foot of enclosed area, with the bottom of each opening no more than one foot above grade. Crawlspace construction below the base flood elevation is capped at four feet of interior height, with the interior grade no more than two feet below the lowest adjacent grade, and is barred entirely where flood velocities exceed five feet per second absent a qualified engineer's design.

Manufactured homes must be elevated to or above the base flood elevation and anchored against flotation and lateral movement, and recreational vehicles are exempt from these elevation rules only if they stay on site fewer than 180 consecutive days or remain fully licensed and ready for highway use.

Violations & Fines

A structure built or substantially improved without the required elevation certification is treated as noncompliant with Title 22 and, under Section 22-3-10, exposes the responsible party to a misdemeanor charge carrying up to a $1,000 fine, up to six months in jail, or both, with each day of the violation a separate offense; the floodplain administrator may also issue a stop-work order under Section 22-3-9 and require costs be paid.

Frequently Asked Questions

How high above base flood elevation must a new home's lowest floor sit?
Section 22-5-2 requires the lowest floor, including any basement, to be elevated at least one foot above the base flood elevation, or to the freeboard elevation if the county has adopted a freeboard standard for that area.
Who has to certify the elevation of a new flood-zone structure?
A registered professional engineer, architect, or land surveyor must submit certified elevations to the Floodplain Administrator confirming Section 22-5-2's standards are met before the structure is considered compliant.
What are the rules for a basement or crawlspace below the flood elevation?
Section 22-5-2 requires flood vents totaling at least one square inch of opening per square foot of enclosed area, with openings no higher than one foot above grade, so water can automatically enter and exit rather than building up pressure on the walls.

Sources & Official References

Other rules in Weber County

All Weber County rules

Compare Weber County to another location·View the Utah environmental rules overview

Get notified when Flood Elevation Requirements in Weber County, UT changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.