Skip to main content
CityRuleLookup

Stanislaus County, CA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Governing section
§16.50.903(B), Utility and Misc. Group U
Elevation standard
Design flood elevation per ASCE 24
Covered structures
Sheds, barns, garages, fences over 6 ft
Alternative to elevation
Dry floodproofing to ASCE 24
Unpermitted/noncompliant work
Presumed violation, misdemeanor

Summary

In Stanislaus County flood hazard areas, accessory structures classified as Utility and Miscellaneous Group U, sheds, barns, private garages, and fences over six feet, among others, must be elevated to or above the design flood elevation under ASCE 24, or dry floodproofed to that same standard, once fully enclosed by walls.

City-specific rules exist: Modesto has its own flood elevation requirements rules that differ from Stanislaus County's county-level regulations. If you live in Modesto, check the city-specific page instead.

Utility and Miscellaneous Group U includes buildings that are accessory in character and miscellaneous structures not classified in any specific occupancy in the building code, including, but not limited to, agricultural buildings, aircraft hangars (accessory to a one- or two-family residence), barns, carports, fences more than six feet (1,829 mm) high, grain silos (accessory to a residential occupancy), greenhouses, livestock shelters, private garages, retaining walls, sheds, stables, and towers...New construction and substantial improvement of such buildings and structures, when fully enclosed by walls, shall be elevated such that the lowest floor, including basement, is elevated to or above the design flood elevation in accordance with ASCE 24 or shall be dry floodproofed in accordance with ASCE 24.

Full Breakdown

903 defines 'Utility and Miscellaneous Group U' for flood-hazard purposes to include agricultural buildings, aircraft hangars accessory to a one- or two-family home, barns, carports, fences more than six feet high, grain silos accessory to a residential use, greenhouses, livestock shelters, private garages, retaining walls, sheds, stables, and towers, essentially the accessory buildings and structures that don't fit a specific occupancy classification elsewhere in the building code. Beyond the building code's fire and life-safety rules, the section layers on flood-specific standards for any of these structures sited in a flood hazard area: new construction and substantial improvements must be anchored to resist flotation, collapse, or lateral movement from flood loads, including buoyancy, under design-flood conditions.

Where the structure is fully enclosed by walls, its lowest floor, including any basement, must be elevated to or above the design flood elevation under ASCE 24, or the structure must be dry floodproofed to that standard instead. If it isn't dry floodproofed, any enclosed area below the design flood elevation is limited to parking, storage, or building access, flood openings must be installed per ASCE 24, flood-damage-resistant materials are required below that elevation, and mechanical, plumbing, and electrical systems must be located or installed per ASCE 24 as well. 902, applies a similar elevation-or-floodproofing standard specifically to detached garages and accessory storage buildings under 600 square feet.

Violations & Fines

Constructing or substantially improving a Group U accessory structure in a flood hazard area without meeting the ASCE 24 elevation or dry-floodproofing standard is a violation of Chapter 16.50: Section 16.50.710 presumes a structure without documented lowest-floor elevation or other required compliance evidence to be in violation until that documentation is produced, and Section 16.50.730 classifies the violation as a misdemeanor, carrying the county's general penalty of up to $1,000, up to six months in jail, or both under Section 1.36.010.

Frequently Asked Questions

Does a shed in a Stanislaus County flood zone need to be elevated?
Yes, if it's classified as a Utility and Miscellaneous Group U structure and fully enclosed by walls. Section 16.50.903(B) requires its lowest floor to be elevated to or above the design flood elevation under ASCE 24, or the structure must be dry floodproofed to that same standard instead.
Are backyard fences regulated under the county's flood rules?
Fences more than six feet high are listed among the Utility and Miscellaneous Group U structures in Section 16.50.903, so within a mapped flood hazard area they must be anchored to resist flotation and lateral movement under design-flood conditions, the same requirement that applies to barns, sheds, and private garages in that zone.
What happens if a flood-zone accessory building isn't elevated correctly?
Section 16.50.710 presumes the structure is in violation if it lacks documentation of its lowest-floor elevation or other required compliance evidence, and Section 16.50.730 makes the violation a misdemeanor. Absent a more specific fine, the county's general misdemeanor penalty in Section 1.36.010 applies: up to $1,000, six months in jail, or both.

Sources & Official References

Other rules in Stanislaus County

All Stanislaus County rules

California rules heatmap·Compare Stanislaus County to another location·View the California environmental rules overview

Get notified when Flood Elevation Requirements in Stanislaus County, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Cities Across Stanislaus County