Modesto, CA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Elevation standard
- Lowest floor at or above base flood elevation
- Freeboard added
- None; BFE is the floor, not BFE-plus
- Certification required
- Registered civil engineer or licensed surveyor
- Basements
- Prohibited outright in residential structures
- Nonresidential option
- Dry floodproofing below BFE with engineer certification
- Accessory structure exception
- One-story, 600 sq ft or less, below BFE allowed
Summary
New and substantially improved homes in a Modesto special flood hazard area must have the lowest floor elevated to or above the base flood elevation shown on the FEMA rate maps. The code sets that BFE line as the floor, with no added freeboard margin, and requires a registered engineer or surveyor to certify the finished elevation.
Residential Construction. All new construction or substantial improvements of residential structures shall have the lowest floor, including basement: (i) In AE, AH, A1-30 zones, elevated to or above the base flood elevation; (ii) In an A zone, without BFE's specified on the FIRM (unnumbered A zone), elevated to or above the base flood elevation, as determined under Section 9-4.402(c). Upon the completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered civil engineer or licensed land surveyor, and verified by the community building inspector to be properly elevated.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 71).
Full Breakdown
201(h) defines base flood elevation, or BFE, as the water surface elevation shown on the Flood Insurance Rate Map for zones AE, AH, A1-30, VE and V1-V30 that results from a flood with a one percent or greater annual chance of occurring, commonly called the 100-year flood. 402(c). The code stops at that line: it does not add a freeboard buffer of extra feet above the BFE the way some jurisdictions do. Once construction is finished, a registered civil engineer or licensed land surveyor must certify the lowest-floor elevation, and a community building inspector must verify it before the Floodplain Administrator accepts it.
501(c)(2): they may be dry floodproofed below the BFE instead of elevated, but only with a registered engineer's or architect's certification that the structure is watertight and can resist hydrostatic and hydrodynamic loads. 201(ah)(2) prohibits all subgrade enclosed areas in residential structures, including below-grade garages and storage, because they count as basements regardless of use. 501(c)(5)(ii) lets a detached, one-story accessory structure of 600 square feet or less sit below the BFE if it is limited to parking or storage, built with flood-resistant materials, anchored against flotation, and designed to let floodwater automatically enter and exit.
Violations & Fines
A structure built below the required base flood elevation without the elevation certificate or other proof of compliance is presumed to be in violation under Section 9-4.201(bd) until that documentation is produced. Section 9-4.402(e) requires the Floodplain Administrator to obtain and keep on file the elevation certifications required by Sections 9-4.501(c)(1) and 9-4.504, and the City can take remedial action under Section 9-4.402(g) against noncompliant construction.
Frequently Asked Questions
How high above the flood line must a Modesto home be built?
Can a basement be built below the base flood elevation?
Who has to certify the finished elevation of a new house?
Can a nonresidential building be floodproofed instead of elevated?
Sources & Official References
Other rules in Modesto
California rules heatmap·Compare Modesto to another location·View the California environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.