Gordon County, GA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Residential lowest floor
- At least 1 foot above base flood elevation
- No base flood elevation mapped
- At least 3 feet above highest adjacent grade
- AO zone without printed depth
- At least 3 feet above highest adjacent grade
- Manufactured home piers
- No less than 36 inches above grade
- Enclosure openings
- Two openings, one square inch per square foot
- Maximum penalty
- $500 fine or five days, or both
Summary
New homes and substantial improvements in unincorporated Gordon County, Georgia must have the lowest floor, including the basement, elevated no lower than one foot above the base flood elevation where that data exists. Where no base flood elevation is mapped, the lowest floor must sit at least three feet above the highest adjacent grade.
A.New residential construction and/or substantial improvements. Where base flood elevation data are available, new construction and/or substantial improvement of any residential structure or manufactured home shall have the lowest floor, including basement, elevated no lower than one (1) foot above the base flood elevation. ... C.In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three (3) feet above the highest adjacent grade at the building site. ... A.All new construction and substantial improvements of residential and nonresidential structures shall have the lowest floor, including basement, elevated to the flood depth number specified on the Flood Insurance Rate Map (FIRM), above the highest adjacent grade. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least three (3) feet above the highest adjacent grade.
Full Breakdown
The elevation standards live in Sections 3.01.18 through 3.01.20 of the Unified Land Development Code and apply in every area of special flood hazard in unincorporated Gordon County. For a new residential structure or manufactured home, or a substantial improvement to one, the lowest floor including the basement must be elevated no lower than one (1) foot above the base flood elevation. Heating and air conditioning equipment, ductwork, and electrical, ventilation, plumbing, and other service facilities must sit at or above that same level. Nonresidential buildings in A1-30, AE, or AH zones can be flood-proofed instead, with walls water tight to one foot above the base flood elevation and a certification from a registered professional engineer or architect.
Enclosures below the lowest floor must be unfinished or flood resistant. They need at least two openings with a total net area of one square inch for every square foot of enclosed area, the bottom of every opening no higher than one foot above grade, and use limited to parking, limited storage of maintenance equipment, or entry. The enclosed area cannot be partitioned or finished into rooms. A manufactured home must have its lowest floor one foot above the base flood elevation, or its chassis supported on reinforced piers of no less than 36 inches above grade.
Where a stream has no base flood elevation, Section 3.01.19 sets the lowest floor no less than three (3) feet above the highest adjacent grade, and one foot above the estimated base flood elevation where a Limited Detail Study has been completed. In AO shallow flooding zones, with depths of one to three feet, the floor goes up to the flood depth number on the FIRM, or at least three feet if none is printed.
The Director of Building Inspections certifies lowest floor elevations in A-zones and AO zones, and the permit holder files an as-built certification after the lowest floor is complete. A variance recipient gets written notice of the gap between the base flood elevation and the proposed lowest floor and a warning that flood insurance will cost more. Critical facilities need access protected to the 500-year flood elevation.
Violations & Fines
Missing the required elevation is a violation of Section 3.01. On conviction the fine is not more than $500, or up to five days in jail, or both, plus all costs and expenses of the case, and each day counts as a separate offense. Work started before certifications are filed is at the permit holder's risk, and failure to submit the certification or fix deficiencies brings a stop-work order on the project.
Frequently Asked Questions
How high must a new house sit above the base flood elevation in unincorporated Gordon County?
What if my lot is in a flood zone with no base flood elevation?
Can I finish the enclosed space under an elevated house?
How is a manufactured home elevated in a flood area in unincorporated Gordon County?
Sources & Official References
Other rules in Gordon County
Compare Gordon County to another location·View the Georgia environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.