Key Facts

Design storm
25-year storm event for stormwater structures
Streams and bridges
Cross drains on live streams and bridges: 100-year storm
Detention trigger
Runoff increase over seven (7) cfs for a 100-year storm
Pipe minimum
Eighteen (18) inches in a County right-of-way
Catch basin spacing
500, 400 or 250 feet by grade
Pond fence
Five (5) feet high with ten (10) foot gate

Summary

In unincorporated Gordon County, Georgia, developers must provide stormwater management structures designed by a state approved professional for a 25-year storm, with stream crossings and bridges designed for a 100-year storm. Section 6.04.01 also ties them to the county floodplain regulations and soil erosion sedimentation ordinance.

These county ordinances apply to unincorporated areas of Gordon County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

A.Stormwater management structures shall be provided by the developer as required in the County floodplain regulations and soil erosion sedimentation ordinance.B.All proposed stormwater management structures shall be designed and certified by an appropriate state approved professional, and shall be subject to the approval of the County.C.Stormwater management structures shall be designed based on a 25-year storm event. The drainage formula used in design of all drainage structures shall be determined by the developer's appropriate state approved professional and based on sound engineering practice.D.All cross drain pipes under streets carrying live streams and all bridges shall be designed for a 100-year storm event. ... G.Energy dissipation devices shall be installed at all discharge points of storm drains in compliance with the approved soil erosion and sediment control plan. At a minimum, an area of rip rap six (6) times the pipe diameter in length and two (2) times the pipe diameter in width shall be provided.

Full Breakdown

Chapter 6 of the Gordon County Unified Land Development Code, Section 6.04.00, sets drainage and stormwater standards for development in unincorporated Gordon County, Georgia. Section 6.04.01 is the general rule. Stormwater management structures shall be provided by the developer as required in the County floodplain regulations and soil erosion sedimentation ordinance. They shall be designed and certified by an appropriate state approved professional and are subject to the approval of the County. The design storm is a 25-year storm event, while all cross drain pipes under streets carrying live streams and all bridges shall be designed for a 100-year storm event. Energy dissipation devices are required at all discharge points of storm drains, with rip rap at least six times the pipe diameter in length and two times the pipe diameter in width. If the exit velocity exceeds ten feet per second, rip rap set in concrete, stilling basins, baffle wall basins, impact blocks or other County approved devices are required.

The detailed standards follow. Section 6.04.02 sets catch basin spacing by grade: 500 feet up to seven percent, 400 feet from seven to ten percent, and 250 feet over ten percent. Section 6.04.03 requires pipes in a County right-of-way to be at least eighteen inches in diameter, and it limits the maximum velocity for unlined ditches to five feet per second design flow. The maximum continuous pipe length is three hundred feet for pipes less than forty-two inches.

Section 6.04.06 governs detention. When an independent state approved professional finds it necessary, a development must submit a certified hydrology study showing that drainage will not adversely affect downstream property owners. If the study shows the development will increase runoff by more than seven cfs for a 100-year storm, storage and release can be required, and no building permit shall be granted unless storage and release is provided for the water volume generated by a 100-year storm. Detention ponds with steep sides and more than two feet of standing water one hour after the storm need a fence at least five feet high with a ten foot gate, and the owner and successors must maintain detention and retention facilities.

Violations & Fines

Sections 6.04.01 through 6.04.06 print no fine of their own. The enforcement lever is the building permit: under Section 6.04.06(B) no building permit is granted unless required storage and release is provided. Gordon County Planning and Development and Public Works review drainage plans, and soil erosion violations fall under the separate county ordinance that Section 6.04.01(A) cites.

Frequently Asked Questions

What storm size must stormwater structures handle in unincorporated Gordon County?
Section 6.04.01(C) requires stormwater management structures to be designed based on a 25-year storm event. Section 6.04.01(D) raises the standard to a 100-year storm event for all cross drain pipes under streets carrying live streams and for all bridges.
When does a development in unincorporated Gordon County need a detention pond?
Under Section 6.04.06(B), if hydrologic studies show runoff will increase by more than seven cfs for a 100-year storm, storage and release can be required. Section 6.04.06(C) lists exceptions, such as adequately sized downstream street culverts that pass the 100-year storm without overtopping the road.
Who has to design and certify the drainage plans?
Section 6.04.01(B) says all proposed stormwater management structures shall be designed and certified by an appropriate state approved professional and are subject to the approval of the County. Section 6.04.03(F) applies the same rule to all manmade stormwater drainage ditches.
Does a stormwater pond have to be fenced?
Section 6.04.06(J) requires fences a minimum of five feet in height with a ten foot wide gate on detention ponds where the sides have a slope of two horizontal to one vertical or greater and the water is deeper than two feet one hour after the storm. Normally dry headwater pools are exempt.

Sources & Official References

Other rules in Gordon County

All Gordon County rules

Compare Gordon County to another location·View the Georgia environmental rules overview

Get notified when Stormwater Management in Gordon County, GA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.