Knox County, TN Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard, BFE zones
- 1 foot above base flood elevation
- Freeboard, unnumbered A zones
- 3 feet above highest adjacent grade
- Administering agency
- Knox County Engineering Department
- Applies to
- New construction and substantial improvements
- Variance body
- County board of adjustments and enforcement
- Citation
- Knox County Code § 34-52
Summary
Knox County requires new construction and substantial improvements in mapped flood-hazard areas to elevate the lowest floor at least one foot above the base flood elevation where BFE data exists, or at least three feet above the highest adjacent grade in unnumbered A zones without BFE data. The Engineering Department administers permits under Sec. 34-52.
(1)Residential construction. Where base flood elevation data is available, new construction or substantial improvement of any residential building (or manufactured home) shall have all utilities [including electrical (utility meters not included), heating, ductwork, ventilating, plumbing, and air conditioning equipment] and the lowest floor, including basement, elevated no lower than one foot above the base flood elevation. ...Within unnumbered A zones, where baseflood elevations have not been established and where alternative data is not available, the engineering department shall require the lowest floor of a building to be elevated or floodproofed to a level of at least three feet above the highest adjacent grade (lowest floor and highest adjacent grade being defined in section 34-12).
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 23).
Full Breakdown
Sec. 34-52 of the Knox County flood damage prevention chapter sets the county's freeboard standard above the National Flood Insurance Program's base flood elevation (BFE). For residential construction, where BFE data is available, new construction or substantial improvement of any residential building or manufactured home must have its utilities, including electrical, heating, ductwork, ventilating, plumbing, and air conditioning equipment, and its lowest floor, including any basement, elevated no lower than one foot above the base flood elevation, a one-foot freeboard above the federal minimum. Nonresidential buildings face the same one-foot-above-BFE standard but may floodproof instead of elevate, provided a registered professional engineer or architect certifies the design meets accepted watertight construction standards and files that certification with the Engineering Department under Sec.
34-32(2). Where a structure sits in an unnumbered A zone, meaning base flood elevation data has not been established and no alternative data is available, the Engineering Department instead requires the lowest floor to be elevated or floodproofed to at least three feet above the highest adjacent grade. Solid perimeter foundation walls used to elevate a structure must include openings sized to equalize hydrostatic flood forces on both sides of the exterior walls. Applicants apply for a development permit through the Engineering Department, which records the as-built lowest-floor elevation certification after construction; failure to submit that certification, or failure to correct a deficiency the department identifies, is grounds for a stop-work order under Sec.
34-32. Variances from these standards go to the county board of adjustments and enforcement under Sec. 34-34, which may not lower flood levels within a designated floodway.
Violations & Fines
Building without a required flood development permit, or below the mandated freeboard, is enforced by the Engineering Department, which can issue a stop-work order for failing to submit the as-built elevation certification or correct a flagged deficiency under Sec. 34-32. A structure lacking the required elevation certificate or other compliance evidence is presumed in violation of the flood damage prevention chapter until documentation is provided, per Sec. 34-12's definition of violation.
Frequently Asked Questions
How high above the flood elevation must a new home be built in Knox County?
What if my property is in an area without an established base flood elevation?
Can a commercial building be floodproofed instead of elevated?
Sources & Official References
Other rules in Knox County
Compare Knox County to another location·View the Tennessee environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.