Skip to main content
CityRuleLookup

Knoxville, TN Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Standard freeboard
1 foot above base flood elevation
TVA dam-controlled rivers
3 feet above base flood elevation
Rivers covered
Tennessee, French Broad, Holston
Applies to
New construction and substantial improvements

Summary

Knoxville requires new and substantially improved buildings in mapped flood zones to elevate the lowest floor at least one foot above base flood elevation, or three feet along TVA dam-controlled rivers.

new construction or substantial improvement of any residential building (or manufactured home) shall have all utilities (including electrical (utility meters not included), heating, ductwork, ventilating, plumbing, and air conditioning equipment) and the lowest floor, including basement, elevated to no lower than one (1) foot above the base flood elevation. Along any TVA dam-controlled river (Tennessee, French Broad, Holston), new construction and/or substantial improvement of any commercial, industrial, or nonresidential building in AE and/or shaded X zones when base flood elevation data is available, shall have all utilities (including electrical (utility meters not included), heating, ductwork, ventilating, plumbing, and air conditioning equipment) and the lowest floor, including basement, elevated to no lower than three (3) feet above the one (1) percent annual chance flood. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate equalization of flood hydrostatic forces on both sides of exterior walls and to ensure the unimpeded movement of floodwaters shall be provided in accordance with standards of article III, section 12-52(3).

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 80).

Full Breakdown

In AE and shaded X zones with base flood elevation data available, new construction or substantial improvement of a residential building or manufactured home must elevate the lowest floor and all utilities to at least one foot above base flood elevation. Along the Tennessee, French Broad, or Holston rivers -- all TVA dam-controlled -- that freeboard rises to three feet above the one percent annual chance flood, applying to commercial, industrial, and nonresidential buildings as well. Foundation walls used to raise a structure need openings that let floodwaters equalize on both sides. Freeboard is defined in § 12-3 as the safety margin above calculated flood levels that accounts for wave action and other unknowns.

Violations & Fines

Building below the required freeboard elevation in a mapped flood zone is a code violation; a structure lacking the required elevation certificate is presumed noncompliant until documentation proves otherwise.

Frequently Asked Questions

How high above flood level must a Knoxville home be built?
At least one foot above the base flood elevation in standard flood zones, or three feet above the one percent annual chance flood along the Tennessee, French Broad, or Holston rivers.
What counts as freeboard in Knoxville's flood code?
A safety margin above the calculated base flood level, defined in § 12-3, meant to cover wave action, debris blockage, and other flood-height uncertainties not captured by the base calculation.

Sources & Official References

Other rules in Knoxville

All Knoxville rules

Compare Knoxville to another location·View the Tennessee environmental rules overview

Get notified when Flood Elevation Requirements in Knoxville, TN changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.