Lee's Summit, MO Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Minimum lowest-floor height
At least 2 feet above base flood elevation
Where it applies
Numbered and unnumbered A zones and AE zones with base flood data
Non-residential alternative
Floodproofing certified by a registered engineer or architect
Enclosure openings
Two openings, 1 square inch per square foot, bottoms within 1 foot of grade
Administrator
City Engineer, serving as Floodplain Administrator
Maximum fine
$500 per offense, each day a separate offense
Improvement trigger
Work over 50 percent of market value within five calendar years

Summary

In Lee's Summit, new homes and substantial improvements in a mapped A or AE flood zone must have the lowest floor, basement and utility equipment included, at least two feet above the base flood elevation. Commercial buildings meet the same two-foot mark or are floodproofed watertight below it with an engineer's certification. The City Engineer administers the rule, and violations are misdemeanors fined up to $500.

In all areas identified as numbered and unnumbered A zones and AE zones, where base flood elevation data have been provided, as set forth in Section 5.170.A.2., the following provisions are required: a. Residential construction: New construction or substantial-improvement of any residential structures, including manufactured homes, shall have the lowest floor, including basement and all mechanical, electrical, and/or other utility equipment, elevated to at least two feet above the base flood elevation. b. Non-residential construction: New construction or substantial-improvement of any commercial, industrial, or other non-residential structures, including manufactured homes, shall have the lowest floor, including basement, elevated to at least two feet above the base flood elevation or, together with attendant utility and sanitary facilities, be floodproofed so that below the base flood elevation the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 55 | Unified Development Ordinance: Supplement 15).

Full Breakdown

Section 5.170(B)(1) of the Unified Development Ordinance sets the elevation standard for Lee's Summit's floodplain overlay. It covers land in numbered and unnumbered A zones and AE zones on the Jackson County flood insurance rate map dated January 20, 2017, as amended (Section 5.140.A), and it applies where base flood elevation data have been provided. The base flood is the flood with a one percent chance of being equaled or exceeded in any given year.

For residential construction, the lowest floor must sit at least two feet above the base flood elevation. The ordinance defines the lowest floor as the lowest floor of the lowest enclosed area, basement included, and it reaches past the floor itself: all mechanical, electrical, and other utility equipment must be raised to the same height. Manufactured homes carry the same two-foot mark. Under Section 5.170.C, a home in an existing manufactured home park can alternatively sit on a chassis supported by reinforced piers at least 24 inches above grade, anchored against flotation, collapse, and lateral movement.

Commercial, industrial, and other non-residential buildings choose between that two-foot elevation and floodproofing, which means the structure is watertight below the base flood elevation, with a registered professional engineer or architect certifying the design to the Floodplain Administrator. Section 5.200.B bars floodproofing of residential structures unless the Federal Insurance Administration grants an exception.

Fully enclosed areas below the lowest floor that are used solely for parking, building access, or storage must have at least two openings totaling not less than one square inch of net area per square foot of enclosed space, with the bottom of every opening no higher than one foot above grade (Section 5.170.B.1.c).

A floodplain development permit is required for each structure (Section 5.150.A). The application must give the lowest-floor elevation in relation to mean sea level, and the City Engineer, who serves as Floodplain Administrator, records the actual elevation of every new or substantially improved structure. An existing structure can be remodeled or enlarged without meeting the elevation standard only while all work in the last five calendar years stays within 50 percent of its current market value (Section 5.170.A.8).

Violations & Fines

Violating Article 5, Division II, including any condition attached to a variance, is a misdemeanor under Section 5.250. A conviction carries a fine of not more than $500.00 plus all costs and expenses of the case, and each day the violation continues counts as a separate offense. The City can also seek injunctive relief through civil remedies against development in the FW and FF overlay districts done without approved permits.

Frequently Asked Questions

How high must a new house in a Lee's Summit flood zone be built?
In a numbered or unnumbered A zone or AE zone with base flood elevation data, the lowest floor must be at least two feet above the base flood elevation. That includes the basement and all mechanical, electrical, and other utility equipment, so a furnace or panel in a basement has to meet the same height. Section 5.170(B)(1)(a) applies the same standard to manufactured homes.
Can a commercial building be floodproofed instead of elevated?
Yes. A commercial, industrial, or other non-residential building can either raise its lowest floor two feet above the base flood elevation or be floodproofed so it is watertight below that elevation, with walls substantially impermeable to water. A registered professional engineer or architect must certify the design, and the certification goes to the Floodplain Administrator, who is the City Engineer.
Do additions and remodels have to meet the elevation rule?
Only when the work is large enough. Under Section 5.170.A.8, a structure can be remodeled or enlarged without conforming to the current elevation requirement while the cumulative value of all work in the last five calendar years does not exceed 50 percent of its current market value. Past that line, the structure must be brought into compliance with Section 5.170.B.1.
What are the rules for a garage or storage area below the lowest floor?
A fully enclosed area below the lowest floor, used solely for parking, building access, or storage, must let floodwater flow in and out. The design needs a registered engineer's or architect's certification or must provide at least two openings with total net area of one square inch per square foot of enclosed area, the bottom of each no higher than one foot above grade.
How does a property owner ask for a variance or appeal a denial?
The Board of Zoning Adjustment hears variance requests and appeals when the City Engineer denies a floodplain development permit or variance (Section 5.210). Appeals of a permit non-issuance or revocation also go to that board under Section 5.260. A party aggrieved by the board's decision, or any taxpayer, can appeal to the Jackson County Circuit Court under RSMo 89.110.

Sources & Official References

Other rules in Lee's Summit

All Lee's Summit rules

Compare Lee's Summit to another location·View the Missouri environmental rules overview

Get notified when Flood Elevation Requirements in Lee's Summit, MO changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Jackson County handle flood elevation requirements.

Independence, MO
Some Restrictions
Kansas City, MO
Some Restrictions