Skip to main content
CityRuleLookup

Reading, PA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard requirement
1.5 feet above Base Flood Elevation
Applies to
Zone AE Without Floodway Subdistrict
Permit required
Floodplain zoning permit before construction
Enforcement
Misdemeanor charge plus fine
Legal basis
Pennsylvania Floodplain Management Act of 1978

Summary

Reading requires new construction and substantial improvements in the Zone AE Without Floodway Subdistrict to elevate the lowest floor at least 1.5 feet above the Base Flood Elevation, a stricter local freeboard standard.

Within the Zone AE Without Floodway Subdistrict, any new construction or substantial improvement shall have the lowest floor (including basement) elevated to at least 1 1/2 feet above the Base Flood Elevation (BFE).

(2)   Within the Zone A Subdistrict, where there are no Base Flood Elevations specified on the FIRM, any new construction or substantial improvement shall have the lowest floor (including basement) elevated to least 1 1/2 feet above the BFE, determined in accordance with § 600-1818C of this Part.

(3)   Within Shallow Flooding Subdistrict (if applicable), any new construction or substantial improvement shall have the lowest floor (including basement) at or above the highest adjacent grade at least as high as the flood depth number specified on the FIRM.

(4)   The design and construction standards and specifications contained in

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-8: Current through August 10, 2026).

Full Breakdown

The City of Reading's floodplain overlay zone ordinance sets a 1.5-foot freeboard above the FEMA Base Flood Elevation (BFE) for new construction and substantial improvements in the Zone AE Without Floodway Subdistrict, stricter than FEMA's zero-freeboard federal minimum. Nonresidential structures can floodproof to the same 1.5-foot mark instead of elevating. Where a Flood Insurance Rate Map shows no BFE (Zone A), the Floodplain Administrator determines an equivalent elevation from the best available data. A floodplain zoning permit from the Floodplain Administrator is required before any construction begins anywhere in the mapped floodplain.

Violations & Fines

Noncompliance is a misdemeanor with a fine under § 600-206, plus the property can be declared a public nuisance and abated by City Council until corrected.

Frequently Asked Questions

Does Reading require higher floor elevations than FEMA's federal minimum?
Yes. FEMA sets zero freeboard as its federal floor, but Reading's ordinance requires new construction and substantial improvements in the Zone AE Without Floodway Subdistrict to elevate 1.5 feet above the Base Flood Elevation.
What if my property is in Zone A with no mapped Base Flood Elevation?
The Floodplain Administrator determines an equivalent elevation from the best available flood data, and new construction or substantial improvement must still be elevated at least 1.5 feet above that determined elevation.

Sources & Official References

Other rules in Reading

All Reading rules

Compare Reading to another location·View the Pennsylvania environmental rules overview

Get notified when Flood Elevation Requirements in Reading, PA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.