Redwood City, CA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Residential freeboard
1 foot above base flood elevation
Nonresidential option
Dry floodproofing with engineer certification
Breakaway wall load range
10 to 20 pounds per square foot
Sub-floor opening ratio
1 sq in per sq ft of enclosed area
Opening height limit
No higher than 1 foot above grade
Certifying professional
Registered engineer or architect

Summary

Redwood City Code Section 41.18 requires new or substantially improved residential structures in any special flood hazard zone to have their lowest floor, including any basement, elevated at least one foot above the base flood elevation. Nonresidential buildings may floodproof instead, and breakaway walls below the floor must meet a set load-resistance range.

Sec. 41.18. - STANDARDS OF CONSTRUCTION: In all areas of special flood hazards, the following standards are required: ...C.Elevation and Floodproofing. ...1.Residential construction, new or substantial improvement, shall have the lowest floor, including basement: a.In an A zone, elevated to a minimum of one (1) foot above the base flood elevation or the design flood elevation, whichever is higher... b.In all other zones, elevated to a minimum of one (1) foot above the base flood elevation or the design flood elevation, whichever is higher. Sec. 41.6. - DEFINITIONS: BREAKAWAY WALLS: ...A breakaway wall shall have a safe design-loading resistance of not less than ten (10) and no more than twenty (20) pounds per square foot. Use of breakaway walls must be certified by a registered engineer or architect...

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Zoning Code: Supplement 29 | City Code: Supplement 61 Update 1).

Full Breakdown

18's elevation and floodproofing standards apply throughout areas of special flood hazard. For residential new construction or substantial improvement, the lowest floor, including any basement, must be elevated to a minimum of one foot above the base flood elevation or the design flood elevation, whichever is higher, in an A zone, and the same one-foot minimum applies in all other zones. Nonresidential new construction or substantial improvement may either meet that same elevation standard or be dry floodproofed instead, so the structure is watertight with walls substantially impermeable to water, has structural components able to resist hydrostatic and hydrodynamic loads, and is certified by a registered engineer or architect to the Floodplain Administrator.

Enclosed areas below the lowest floor used only for parking, building access or storage must be designed to automatically equalize floodwater pressure, generally through at least two openings totaling one square inch of net area per square foot of enclosed area, with the bottom of openings no higher than one foot above grade, or through an engineer's or architect's certification. 6 defines them as "breakaway walls" that must be designed to break away under abnormally high tides or wave action without damaging the structure's integrity, must have a safe design-loading resistance of not less than ten and no more than twenty pounds per square foot, and must be certified by a registered engineer or architect. 18(C)(3).

Violations & Fines

Constructing or substantially improving a residential structure in a special flood hazard area with its lowest floor below the required one-foot freeboard above the base flood elevation, or installing enclosure walls that do not meet the ten-to-twenty pound breakaway wall load standard or lack the required engineer's or architect's certification, is a violation of Section 41.18 and, under Section 41.9, constitutes a misdemeanor subject to City Council enforcement action.

Frequently Asked Questions

How high above flood level must my house be built in Redwood City?
Section 41.18(C)(1) requires the lowest floor of new or substantially improved residential construction, including any basement, to be elevated at least one foot above the base flood elevation or the design flood elevation, whichever is higher, in every flood zone the City regulates.
Can a nonresidential building in a flood zone skip elevating the floor?
Yes, if it is dry floodproofed instead: Section 41.18(C)(2) allows the structure to be made watertight with impermeable walls and flood-resistant structural components, certified by a registered engineer or architect to the Floodplain Administrator.
What load standard applies to breakaway walls under a flood-zone house?
Section 41.6 requires breakaway walls to carry a safe design-loading resistance of not less than ten and no more than twenty pounds per square foot and to be certified by a registered engineer or architect so they fail before damaging the structure above.
Can I build a detached garage below the base flood elevation?
Yes, under Section 41.18(C)(5)(b), a detached garage or small accessory structure used only for parking or storage may have its floor below the BFE if built with flood-resistant materials, anchored against flotation, and designed to let floodwater enter and exit automatically.

Sources & Official References

Other rules in Redwood City

All Redwood City rules

California rules heatmap·Compare Redwood City to another location·View the California environmental rules overview

Get notified when Flood Elevation Requirements in Redwood City, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.