St. Petersburg, FL Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard requirement
base flood elevation plus 2 feet
AO Zone alternative
FIRM depth number plus 2 ft, or 4 ft min
Coastal high hazard zones
lowest structural member at BFE+2 ft
Fill for structural support
prohibited in V/VE and Coastal A zones
Compliance proof
Elevation Certificate at framing and final inspection

Summary

St. Petersburg's local amendment to the Florida Building Code Residential requires new and substantially improved homes in flood hazard areas, including Coastal A Zones, to elevate their lowest floor to at least two feet above base flood elevation, or the design flood elevation, whichever is higher: a two-foot freeboard above the FEMA minimum.

R322.2.1 Elevation requirements. 1.Buildings and structures in flood hazard areas, including flood hazard areas designated as Coastal A Zones shall have the lowest floors elevated to or above the base flood elevation plus 2 feet (610 mm), or the design flood elevation, whichever is higher. 2.In areas of shallow flooding (AO Zones), buildings and structures shall have the lowest floor (including basement) elevated to a height above the highest adjacent grade of not less than the depth number specified in feet (mm) on the FIRM plus 2 feet (610 mm), or not less than 4 feet (1220 mm) if a depth number is not specified.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 54).

Full Breakdown

1, Elevation requirements. As enacted, it requires that buildings and structures in flood hazard areas, including areas designated Coastal A Zones, have their lowest floors elevated to or above the base flood elevation plus 2 feet, or the design flood elevation, whichever is higher. In AO Zones of shallow flooding, the lowest floor, including any basement, must sit above the highest adjacent grade by at least the depth number shown on the FIRM plus 2 feet, or not less than 4 feet if no depth number is specified.

2 for enclosed areas used solely for parking, building access or storage. 2, covering coastal high hazard areas and Coastal A Zones, elevates the bottom of the lowest horizontal structural member, not just the floor, to that same base-flood-elevation-plus-2-feet or design-flood-elevation standard, and flatly bans use of fill for structural support and basements below grade on all sides in those zones. 9 as the elevation of the design flood, including wave height, referenced to the datum on the city's legally designated flood hazard map.

Violations & Fines

Structures in A Zones must submit an Elevation Certificate (Under Construction) to the Floodplain Manager once the lowest floor is placed and before further vertical construction, per Section 16.40.050.6.6, with a second Elevation Certificate (Finished Construction) required at final inspection; V and VE Zone structures instead submit certification at placement of the lowest horizontal structural member. A building lacking that documented lowest-floor elevation is presumed to be a violation under Section 16.40.050.8.1 until the certificate is produced.

Frequently Asked Questions

How high above base flood elevation must I build my house in St. Petersburg?
At least 2 feet, per the city's amendment to Florida Building Code Section R322.2.1 at City Code Section 8-36(b)(2): the lowest floor must sit at or above the base flood elevation plus 2 feet, or the design flood elevation if that number is higher.
Does St. Petersburg's freeboard rule apply to Coastal A Zones?
Yes. Section R322.2.1, as amended by Section 8-36(b)(2), explicitly includes flood hazard areas designated as Coastal A Zones in the same base-flood-elevation-plus-2-feet standard that applies to other A Zones.
What proof of elevation do I need to submit during construction?
An Elevation Certificate (Under Construction) once the lowest floor, or, in V/VE Zones, the lowest structural member, is placed and before further vertical work, per Section 16.40.050.6.6, followed by an Elevation Certificate (Finished Construction) at final inspection.

Sources & Official References

Other rules in St. Petersburg

All St. Petersburg rules

Florida rules heatmap·Compare St. Petersburg to another location·View the Florida environmental rules overview

Get notified when Flood Elevation Requirements in St. Petersburg, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.