Taylor, MI Environmental Rules: Flood Zones (2026)

Significant Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

FEMA flood zone rules in Taylor, MI, also called floodplain regulations or special flood hazard area (SFHA) rules, determine flood insurance requirements and elevation standards for new construction.

Key Facts

Governing sections
Appendix A Sec. 10.02 and Sec. 10.04(c)
Flood map source
FEMA flood insurance rate map dated 10-17-1986
Residential elevation
Lowest floor 1 foot above base flood level
Nonresidential option
Elevate 1 foot or floodproof, engineer-certified
Variances
Not permitted in the floodplain overlay district
Reviewing office
Development services department / city engineer

Summary

In the City of Taylor, Michigan, new construction inside the Floodplain Overlay District must elevate its lowest floor one foot above base flood level or floodproof to that standard, and variances are never granted there. Taylor Zoning Ordinance Appendix A Sec. 10.02 and Sec. 10.04(c) set the rule, tied to the 1986 FEMA flood insurance rate map.

(c)Uses permitted by the zoning districts otherwise established for the parcel subject to the regulations of the district.(1)All new construction and substantial improvements of residential structures shall have the lowest floor elevated one foot above the base flood level.(2)All new construction and substantial improvements of nonresidential structures shall have either:a.The lowest floor elevated one foot above the base flood level.b.Be constructed such that below base flood level, together with attendant utility and sanitary facilities, is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy ... (3)In the area below the upper limit of the floodplain area boundary, dumping, or backfilling with any material in any manner is prohibited, unless through compensating excavation and shaping of the floodplain area its flow and impoundment capacity will be maintained or improved as approved by the city engineer.

Full Breakdown

Article 10 of Taylor's zoning ordinance overlays a Floodplain Overlay District on top of the underlying zoning shown on the city's zoning map, based on the 100-year flood boundary from the FEMA flood insurance rate map dated October 17, 1986 (Sec. 10.03). Sec. 10.02 makes the floodplain rules apply in addition to, or in lieu of, the underlying district's requirements, gives the article precedence over any competing local law, and flatly bars variance approvals inside the district. Sec. 10.04(c) then sets the construction standard: new construction and substantial improvements of residential structures must have the lowest floor elevated one foot above the base flood level, and nonresidential structures must either meet that same one-foot elevation or be floodproofed watertight below base flood level, certified by a registered professional engineer or architect as able to resist hydrostatic and hydrodynamic loads.

Dumping or backfilling below the upper limit of the floodplain boundary is prohibited unless compensating excavation preserves flow and impoundment capacity, as approved by the city engineer. Sec. 10.05 requires applicants to submit engineering studies when a city agency needs them to assess flooding effects, plus proof of any required state floodplain permit before construction proceeds.

Violations & Fines

Building below the required elevation or filling the floodplain without city engineer approval is a zoning violation. Under the Code's general penalty section, Sec. 1-13, an unclassified violation is a misdemeanor punishable by a fine up to $500 plus costs and up to 90 days imprisonment, or a municipal civil infraction fine of $50 to $500 plus costs, with each continuing day treated as a separate offense and the city able to seek injunctive relief.

Frequently Asked Questions

Can I get a variance to build lower than the flood elevation in Taylor?
No. Sec. 10.02(d) states variance approvals shall not be given within the floodplain overlay district, so any new construction there must meet the elevation or floodproofing standard in Sec. 10.04(c) without exception.
How high must a new house be built in Taylor's floodplain overlay?
Sec. 10.04(c)(1) requires the lowest floor of new construction or substantial improvement of a residential structure to be elevated one foot above the base flood level shown on the FEMA map.
What if I want to fill in part of a floodplain lot in Taylor?
Sec. 10.04(c)(3) prohibits dumping or backfilling below the upper limit of the floodplain area boundary unless compensating excavation maintains or improves the flow and impoundment capacity, subject to city engineer approval.

Sources & Official References

Other rules in Taylor

All Taylor rules

Compare Taylor to another location·View the Michigan environmental rules overview

Get notified when Flood Zones in Taylor, MI changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Zones in Nearby Cities

How other cities in Wayne County handle flood zones.

Westland, MI
Some Restrictions
Dearborn, MI
Some Restrictions
Detroit, MI
Some Restrictions
Livonia, MI
Significant Restrictions