Schenectady, NY Fire Regulations: Propane Storage (2026)
Key Facts
- Indoor liquid LP gas storage
- Prohibited outright
- Indoor LP gas piping
- Prohibited
- Vaporizing method ban
- No open flame or open electrical coil
- Shutoff location
- Must be outside the building
Summary
Schenectady's Housing Standards flatly prohibit storing undiluted liquefied petroleum gas in liquid form inside any building, and bar routing it through indoor piping systems. Container hookups and shutoffs carry their own safety specifications under the same section.
Liquefied petroleum gas. (1) Undiluted liquefied petroleum gas in liquid form shall not be stored in buildings and shall not be conveyed through piping equipment and systems in buildings. (2) Liquefied petroleum gas shall not be vaporized by devices utilizing open flame or open electrical coil. (3) Where two or more containers are installed, connection shall be arranged so that containers can be replaced without shutting off the flow of gas to the equipment. (4) Containers shall be designed, stored and located so as not to be a hazard to the premises served or to the surrounding property. (5) Systems shall be provided with safety devices to relieve excessive pressures and shall be arranged so that the discharge terminates at a safe location. (6) Systems shall have at least one accessible means for shutting off the gas. Such means shall be located outside the building and shall be maintained in good operating condition.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4990798; v11 updated 2026-04-13; through 04-13-2026).
Full Breakdown
Chapter 167, § 167-35F, Liquefied Petroleum Gas, sits inside the Fuel Gas article of the City's Housing Standards. Subsection (1) is an outright prohibition: undiluted liquefied petroleum gas in liquid form shall not be stored in buildings, and it also may not be conveyed through piping equipment and systems inside buildings. Subsection (2) adds that LP gas cannot be vaporized using devices with an open flame or an open electrical coil, closing off a common workaround for warming a tank faster. The remaining subsections regulate how outdoor container systems must be built: where two or more containers are installed, the connections must let one be swapped out without shutting off gas flow to connected equipment; containers themselves must be designed, stored and located so they don't endanger the served premises or neighboring property; the system needs safety devices to relieve excess pressure with the discharge routed to a safe location; and every system must have at least one accessible shutoff, located outside the building, kept in good operating condition.
Read together, the section makes clear that liquid-phase LP gas storage belongs outside the structure entirely, with the container, its shutoff and its pressure-relief hardware all sited and maintained so a leak or overpressure event can't become a fire spreading into the building itself.
Violations & Fines
Chapter 167 violations are enforced through § 167-14: the Building Inspector issues a written notice of violation specifying the deficiency and a compliance deadline, and failure to abate lets the Corporation Counsel seek a court order compelling compliance. In emergencies presenting an immediate hazard, such as gas stored or piped in violation of § 167-35F, the Building Inspector may act at once to abate the danger, including vacating the structure.
Frequently Asked Questions
Can I store a propane tank inside my house in Schenectady?
How can I safely thaw or warm a propane tank in Schenectady?
Where must a propane system's shutoff valve be located under Schenectady's code?
Sources & Official References
Other rules in Schenectady
New York rules heatmap·Compare Schenectady to another location·View the New York fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.