Decatur, AL Hurricane Preparedness: Flood Elevation (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

No BFE data
Lowest floor at least 3 feet above highest adjacent grade
Fallback figure
4 feet above grade when one-foot freeboard applies
AO zones
FIRM depth number plus one foot of freeboard
AO zone with no depth
At least 3 feet above highest adjacent grade
BFE data trigger
Developments over 50 lots or five acres
Manufactured home chassis
36 to 60 inches above highest adjacent grade

Summary

In the City of Decatur, Alabama, City Code § 25-32(d)4 requires the lowest floor in flood areas without base flood elevation data to sit at least three feet above the highest adjacent grade, and § 25-32(e)1 requires shallow flooding AO zones to add one foot of freeboard to the mapped depth number.

4.In SFHAs without BFE data, new construction and substantial improvements of existing structures shall have the lowest floor (for the lowest enclosed area; including basement) elevated no less than three (3) feet above the highest adjacent grade. As the requirements set forth in section 25-32(b)1. and (b)2. stipulate the lowest floor to be elevated no less than one foot about the BFE, then the structure for this condition shall be elevated no less than four (4) feet about the highest adjacent grade. ... (e)Standards for areas of shallow flooding (AO zones). ... 1.All new construction and substantial improvements of residential and nonresidential structures shall have the lowest floor, including basement, elevated above the highest adjacent grade at least as high as the depth number specified on the flood insurance rate map (FIRM) plus one foot of freeboard. If no depth number is specified, the lowest floor (including basement) shall be elevated at least three (3) feet above the highest adjacent grade.

Full Breakdown

Decatur's floodplain ordinance covers two situations where no simple base flood elevation is printed. In approximate A-zone streams, where the map shows a stream but no base flood data, new construction and substantial improvements must have the lowest floor, including the lowest enclosed area and basement, elevated no less than three feet above the highest adjacent grade. Because the standard elsewhere calls for one foot above the BFE, the code states the structure must in this case sit no less than four feet above the highest adjacent grade. Before that fallback applies, § 25-32(d)2 has the floodplain administrator obtain and use any scientific or historic BFE and floodway data from a federal, state or other source. New subdivisions and developments over 50 lots or five acres, whichever is less, must supply BFE data.

In AO zones, where base flood depths run one to three feet above ground with no clearly defined channel, the lowest floor must be elevated above the highest adjacent grade at least as high as the depth number on the FIRM plus one foot of freeboard. If the map carries no depth number, the floor must be at least three feet above the highest adjacent grade. Non-residential buildings can be floodproofed in lieu of elevation to that level with an engineer's or architect's certification, and drainage paths must guide floodwater around and away from the structure.

Manufactured homes without a BFE must have the chassis supported no less than 36 inches and up to a maximum of 60 inches above the highest adjacent grade, with utilities at least three feet above grade. The floodplain administrator certifies the lowest floor elevation and the record becomes a permanent part of the permit file.

Violations & Fines

Work outside the elevation standards is a violation of the floodplain ordinance. Under § 25-30(h), it is a misdemeanor with a fine up to $500.00, up to six months in jail, or both, plus costs, and each day after the notice of violation is a separate offense. The city can issue stop-work orders, revoke permits, withhold a certificate of occupancy, or invoke a Section 1316 declaration ending flood insurance eligibility.

Frequently Asked Questions

How high must a house be in a Decatur flood area with no base flood elevation?
Under § 25-32(d)4, new construction and substantial improvements must have the lowest floor elevated no less than three feet above the highest adjacent grade. The code adds that where the one foot above BFE standard is folded in, the structure must be no less than four feet above the highest adjacent grade.
What is the elevation rule in a Decatur AO zone?
Section 25-32(e)1 requires the lowest floor, including the basement, to be elevated above the highest adjacent grade at least as high as the depth number on the flood insurance rate map plus one foot of freeboard. If no depth number is specified, it must be at least three feet.
Does Decatur use flood data from other sources when the map has none?
Yes. Section 25-32(d)2 directs the floodplain administrator to obtain, review and reasonably use any scientific or historic BFE and floodway data from a federal, state or other source. The three and four foot fallback applies only if no such data is available.
Can a store in an AO zone floodproof instead of raising the floor?
Under § 25-32(e)2, new construction and substantial improvement of a non-residential structure can be floodproofed in lieu of elevation to the specified flood level, or three feet above highest adjacent grade if no depth number exists. An Alabama licensed engineer or architect must certify the design.

Sources & Official References

Other rules in Decatur

All Decatur rules

Compare Decatur to another location·View the Alabama hurricane preparedness overview