Skip to main content
CityRuleLookup

Lafayette Parish, LA Hurricane Preparedness: Flood Elevation (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Elevation standard
Lowest floor 12 in. above BFE
Territorial reach
City of Lafayette + unincorporated parish
Enforcing official
Development and Planning Director
Penalty
Up to $100/day, 30 days jail
Flood study basis
FEMA flood insurance study, 12-21-2018

Summary

New homes and substantially improved residences in Lafayette's mapped flood hazard areas must have their lowest floor built at least 12 inches above the base flood elevation, per the parish's floodplain code.

These county ordinances apply to unincorporated areas of Lafayette Parish. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

Residential construction: New construction and substantial improvement of any residential structure shall have the lowest floor (including basement and garage, or carport) elevated to a minimum of 12 inches above the base flood elevation. Attached garages and utilities (including electrical, heating, ductwork, ventilating, plumbing, and air conditioning equipment) must also be protected to 12 inches above the base flood elevation.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 65).

Full Breakdown

Lafayette City-Parish Consolidated Government's floodplain code requires new construction and substantial improvements to any residential structure in a mapped special flood hazard area to elevate the lowest floor -- including basement, garage, or carport -- at least 12 inches above the base flood elevation (BFE). Attached utilities like HVAC, plumbing, and electrical must also sit 12 inches above BFE. Nonresidential buildings get the same 12-inch elevation rule or can be floodproofed instead. The requirement applies inside the City of Lafayette and the unincorporated parish alike -- Broussard, Carencro, Duson, Scott, Youngsville, and Milton set their own rules.

Violations & Fines

Building below the 12-inch freeboard mark without a floodproofing certification is a misdemeanor punishable by up to $100 per day and 30 days in jail; each day of noncompliance is a separate violation.

Frequently Asked Questions

Does the 12-inch rule apply outside Lafayette city limits?
Yes. Sec. 26-702 applies the floodplain code to the City of Lafayette and the unincorporated parish alike; Broussard, Carencro, Duson, Scott, Youngsville, and Milton administer their own separate codes.
Can a nonresidential building skip the elevation requirement?
Yes, if floodproofed instead: walls must be watertight below the BFE plus 12 inches, and a registered engineer or architect must certify the design to the floodplain administrator.

Sources & Official References

Other rules in Lafayette Parish

All Lafayette Parish rules

Compare Lafayette Parish to another location·View the Louisiana hurricane preparedness overview

Get notified when Flood Elevation in Lafayette Parish, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation in Cities Across Lafayette Parish