Southfield, MI Landscaping Rules: Rainwater Harvesting (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing section
City Code § 5.60-D(B), (C), (I), (K), (N)
Foundation clearance
Overflow discharge 10 ft. minimum from foundation
Cistern construction
Watertight, sealed joints, smooth interior
Buried cistern access
Observation riser 6 in. minimum above grade
Winter rule
Systems disconnected and emptied before freezing

Summary

The City of Southfield regulates rainwater harvesting hardware under City Code § 5.60-D. Rain barrels and cisterns must be positioned to catch rooftop runoff, built watertight with sealed joints and a smooth interior, and set up to overflow safely at least ten feet from the building foundation, with buried cisterns requiring an observation riser standing at least six inches above grade.

B.Rain barrels and cisterns should be positioned to receive rooftop runoff.C.Provide for the use or release of stored water between storm events in order for the necessary stormwater storage volume to be available. ... I.The proximity to building foundations must be considered from overflow conditions. Overflow discharge must be a minimum of ten (10) feet from building foundation. ... K.Cisterns must be watertight (joints sealed with nontoxic waterproof material) with a smooth interior surface, and capable of receiving water from rainwater harvesting system. ... N.Observation risers must be at least six (6) inches above grade for buried cisterns.

Full Breakdown

Section 5.60-D lays out Southfield's design checklist for rainwater harvesting hardware, separate from its greywater-plumbing safety rules in the same section. Paragraph B requires rain barrels and cisterns to be positioned to actually receive rooftop runoff, and paragraph C requires the system to allow stored water to be used or released between storm events so there is always available storage volume for the next rain. Construction standards follow in paragraph K: cisterns must be watertight, with joints sealed using nontoxic waterproof material and a smooth interior surface capable of receiving harvested water without leaking or degrading.

Paragraph L requires covers and lids with a tight fit to keep out surface water, animals, dust, and light, while paragraph M requires a positive overflow outlet a few inches from the top of the cistern and paragraph N requires observation risers on buried cisterns to stand at least six inches above grade so the system can be inspected and maintained. Placement relative to the building itself is also regulated: paragraph I requires overflow discharge to be a minimum of ten feet from the building foundation to avoid feeding water back toward the structure.

Climate-driven maintenance is built in too, paragraph J requires capture and reuse systems to be disconnected and emptied during winter to prevent freeze damage, and paragraph P requires rain barrels to include a release mechanism, such as a soaker hose, so stored water can be slowly drained onto a landscaped area between storms rather than sitting stagnant.

Violations & Fines

A rainwater harvesting installation that lacks the watertight cistern construction, overflow clearance, or winter shutdown required by § 5.60-D can be flagged during site plan or landscaping plan review, and an installed system found leaking, discharging within ten feet of a foundation, or left connected through winter freeze conditions is out of compliance with the design standard and subject to correction.

Frequently Asked Questions

How far from my house can a rain barrel overflow discharge in Southfield?
The overflow discharge must be at least ten feet from the building foundation under § 5.60-D(I), a placement rule intended to keep excess harvested rainwater from pooling against or seeping into the structure it was collected from.
Do I need to winterize a rainwater harvesting system in Southfield?
Yes. Section 5.60-D(J) requires capture and reuse systems to be disconnected and emptied during winter to prevent freezing, since a frozen, cracked cistern or barrel can no longer hold water safely once temperatures warm up.
What construction standard applies to a buried cistern in Southfield?
Section 5.60-D(K) requires the cistern to be watertight with joints sealed in nontoxic waterproof material and a smooth interior surface, and § 5.60-D(N) additionally requires a buried cistern's observation riser to stand at least six inches above grade for inspection access.

Sources & Official References

Other rules in Southfield

All Southfield rules

Compare Southfield to another location·View the Michigan landscaping rules overview

Get notified when Rainwater Harvesting in Southfield, MI changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.