Palm Beach County, FL Noise from Specific Sources: HVAC & Mechanical Noise (2026)
Key Facts
- Residential receiving land
- 60 dB at any time, in both the USA and RSA columns
- Commercial non-residential land
- 70 dB at any time, all sources
- Violation threshold
- Over the limit for more than 10% of a measurement period of at least 10 minutes
- Meter
- Type 2 or equivalent, A-Weighting Scale, ANSI standards
- Where it is measured
- At or within the complaining landowner's boundary, inside the receiving land
- Enforcement
- Code Enforcement Officer investigates; County Attorney seeks injunction
- Screening of new equipment
- Opaque barrier on all sides, as tall as the highest point of the equipment
Summary
Palm Beach County caps sound from fixed mechanical equipment, the row of Table 5.E.4.B that reaches air conditioning condensers and similar units, at 60 dB at any time of day when the receiving land is residential. The same 60 dB figure prints under both the USA and RSA columns. Commercial and other non-residential receiving land is capped at 70 dB. The limit applies across unincorporated Palm Beach County.
No person shall operate or cause to be operated any source of sound from any location in such a manner as to create a sound level which exceeds the limits set forth below in Table 5.E.4.B, Maximum Sound Levels, for more than ten percent of any measurement period, which period shall not be less than ten minutes. Sound Level Measurement Compliance shall be determined with a Type 2 or equivalent sound level meter using the A-Weighting Scale in accordance with the standards of the American National Standards Institute (ANSI). All measurements shall be made with a sound meter at or within the boundary of the complaining landowner within the property lines of the receiving land. Table 5.E.4.B - Maximum Sound Levels Receiving Land Use Type Sound Source Time of Day Max. Sound Level USA RSA Residential Fixed mechanical equipment Any time 60 dB 60 dB [...] Commercial Non-Residential All sources Any time 70 dB 70 dB
Full Breakdown
Table 5.E.4.B in ULDC Art. 5.E.4.B.2 sets the number. For a residential receiving property, the Fixed mechanical equipment row reads Any time, 60 dB in the USA column and 60 dB in the RSA column. There is no night discount for this source. The residential All other sources row steps down from 60 dB (55 dB in the RSA column) between 7:00 a.m. and 8:00 p.m. to 55 dB (50 dB in the RSA column) from 8:00 p.m. to 10:00 p.m. and 50 dB from 10:00 p.m. to 7:00 a.m., but fixed mechanical equipment sits on its own row at a flat 60 dB around the clock. On commercial non-residential receiving land, the All sources row sets 70 dB at any time in both columns. Permanent generators have their own 75 dB row and are governed by Art. 5.B.1.A.19.
Art. 5.E.4.B.2.a also fixes how a reading counts. A source violates the limit only if it exceeds the table figure for more than ten percent of a measurement period, and the period cannot be shorter than ten minutes. In a ten-minute period that means a compressor over 60 dB for one minute passes and one over 60 dB for more than one minute fails. Compliance is determined with a Type 2 or equivalent sound level meter on the A-Weighting Scale under American National Standards Institute (ANSI) standards. Readings are taken at or within the boundary of the complaining landowner, within the property lines of the receiving land, so the measurement is made on the neighbor's side of the line, not beside the unit.
The chapter applies to all land in the unincorporated area of Palm Beach County unless exempt under Art. 5.E.1.E, Upgrade Agreement (Art. 5.E.4.A.2). Where this chapter conflicts with another code provision, county ordinance or state law, the more stringent applies (Art. 5.E.4.A.3). The exemption list in Art. 5.E.4.A.5 covers road and rail transportation, airports, government-sanctioned events on public land, crowd noise at sporting events, the Research and Technology Overlay, bona fide agriculture, and temporary portable generators used during utility outages. Ordinary HVAC equipment is not on it.
Installation rules sit next door in Art. 5.B.1.A.20, Mechanical Equipment. Setback exceptions follow Art. 3.D.1.D.5 and height exceptions follow Art. 3.D.1.E.4. New and replacement equipment must be screened on all sides by an opaque barrier, or equivalent landscaping for ground-mounted equipment, to a height at least equal to the highest point of the equipment. Roof-mounted equipment under one foot tall, measured from the roof deck and painted to match the structure, is exempt from that screening.
Violations & Fines
Under Art. 5.E.4.B.3.a, any sound from any source above the Chapter's limits is declared a public nuisance. After a written complaint, the Code Enforcement Officer can investigate and ask the County Attorney to file injunctive proceedings to abate the nuisance, and those proceedings are cumulative with the penalties provided in the Code. The text of Art. 5.E.4.B.3 prints no dollar fine, so the remedy it spells out is a court order to stop the noise. Sound from a source the Code does not limit is treated as a civil issue under Art. 5.E.4.B.3.b.
Frequently Asked Questions
How loud can a neighbor's air conditioner be in unincorporated Palm Beach County?
Does the HVAC limit get lower at night?
Can a unit that only runs for a short cycle violate the limit?
Who enforces the limit and what can they do?
Does new HVAC equipment have to be screened?
Sources & Official References
Other rules in Palm Beach County
Florida rules heatmap·Compare Palm Beach County to another location·View the Florida noise from specific sources overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.