West Bloomfield, MI Outdoor Cooking: Smoker Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Permit
Building permit required before install
Off-property setback
25 feet from nearest building
Same-lot setback
15 feet from any structure
Woodland setback
15 feet from mapped woodland
Stack height
At least 8 feet above grade
Attendance
Constantly attended until extinguished
Max penalty
$500 fine / 93 days jail

Summary

West Bloomfield Township requires a building permit before installing an outdoor fireplace or outdoor stove, and Township Code Sec. 11-79(a) sets fixed setbacks: twenty-five feet from any building not on the same lot, fifteen feet from structures on the same property, and fifteen feet from mapped woodland. The unit needs an eight-foot stack, constant attendance while lit, and a fire extinguisher on hand.

a)Outdoor fireplace/outdoor stove. Installation and use of an outdoor fireplace or outdoor stove shall comply with the following:1.A building permit shall be obtained prior to installation of an outdoor fireplace or stove. The application for building permit shall include construction plans.2.An outdoor fireplace or stove shall be setback at least twenty-five (25) feet from the nearest building which is not on the same property as the outdoor fireplace or stove.3.An outdoor fireplace or stove shall be setback at least fifteen (15) feet from all structures constituting part of a building. ... 6.An outdoor fireplace or stove shall have a stack or chimney that extends at least eight (8) feet above the ground surface. ... 7.A fire in an outdoor fireplace or stove shall be constantly attended until the fire is extinguished.8.A functioning fire extinguisher shall be readily accessible to users of the outdoor fireplace or stove.

Full Breakdown

Chapter 11, Article V of the West Bloomfield Township Code covers permanent outdoor cooking and heating appliances separately from portable fire pits. Under Sec. 11-79(a), an outdoor fireplace or outdoor stove, defined in Sec. 11-77 as a boiler, stove, oven or furnace located outdoors and fueled by natural gas, propane or clean wood, cannot go in without Planning and Development first issuing a building permit backed by construction plans. Once installed, the appliance must sit at least twenty-five feet from the nearest building that is not on the same property, at least fifteen feet from any structure on the same lot, and at least fifteen feet from a woodland as mapped under the zoning ordinance's Sec.

2.1.127; it cannot be placed inside a wetland delineated under Sec. 12-5. The stack or chimney must rise at least eight feet above grade, though the fire chief can approve a shorter stack case by case if the manufacturer's specifications call for it and the lower exhaust will not create a smoke nuisance for neighbors. While burning, the appliance must be constantly attended until fully extinguished, and a working fire extinguisher has to be within reach of anyone using it. Sec. 11-78(f) separately treats any burning, permitted or not, as a nuisance if it produces noxious odors or excessive dust and ash reaching nearby properties, letting a fire code official, police officer, or code enforcement officer order it extinguished on the spot.

Violations & Fines

Article V of Chapter 11 carries no separate penalty clause, so a violation falls under the Code's general penalty, Sec. 1-10: a misdemeanor punishable by up to ninety-three days in jail and/or a $500 fine, with each day of a continuing violation counted as a separate offense. The West Bloomfield Fire Department and code enforcement officers can also order an offending fire extinguished immediately, and the township can recover its response and remediation costs from the responsible party under Sec. 11-83.

Frequently Asked Questions

Do I need a permit for an outdoor pizza oven or wood stove in West Bloomfield Township?
Yes. Sec. 11-79(a) requires a building permit with construction plans before installing any outdoor fireplace or outdoor stove, whether it burns clean wood, natural gas, or propane. Planning and Development reviews the application before you build.
How far from my house does an outdoor stove have to sit?
At least fifteen feet from any structure on your own property and twenty-five feet from the nearest building on a neighboring lot, per Sec. 11-79(a). It also needs fifteen feet of clearance from mapped woodland and cannot sit in a wetland.
Does the chimney have to be a certain height?
Yes, at least eight feet above the ground under Sec. 11-79(a). The fire chief can approve a shorter stack only if the manufacturer requires it and the lower smoke will not bother neighboring properties.
What happens if my outdoor stove creates smoke complaints?
Sec. 11-78(f) treats nuisance odor, dust, or ash reaching nearby properties as prohibited burning, and a fire code official, police officer, or code enforcement officer can order it extinguished immediately regardless of your permit.

Sources & Official References

Other rules in West Bloomfield

All West Bloomfield rules

Compare West Bloomfield to another location·View the Michigan outdoor cooking overview

Get notified when Smoker Rules in West Bloomfield, MI changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.