Ascension Parish, LA Outdoor Lighting: Dark Sky Rules (2026)

Light Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing section
UDC § 17-2088(A)(3)
Preferred fixture
Less-than-90-degree cutoff luminaire
Flagged fixture
No-cutoff luminaire, glare/safety hazard
Review authority
Zoning Official, site plan review
Penalty
$50-$500 fine or up to 30 days jail
Applies to
Unincorporated Ascension Parish only

Summary

In unincorporated Ascension Parish, the Unified Land Development Code sets a minimal exterior lighting standard at UDC Section 17-2088(A)(3): a fixture with no cutoff produces unsightly glare and a safety hazard, while a less-than-90-degree cutoff luminaire is preferred because its design keeps the light source from being visible off site.

These county ordinances apply to unincorporated areas of Ascension Parish. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

3.Commentary. This regulation represents the minimal standard for exterior lighting. The developer or property owner should evaluate the following circumstances:a.No cutoff luminaire. When the light source has no cutoff, exterior lighting fixtures can produce unsightly glare which may result in a safety hazard. (A cutoff is the point at which all light emitted from a light is completely eliminated-cutoff at a specific angle to the ground.)b.Less than 90-degree cutoff luminaire. These lights are preferable because the design of the fixture can ensure that the light source is not visible off site.

Full Breakdown

Ascension Parish addresses fixture shielding under Section 17-2088, Lighting standards, within the Development requirements article of the Unified Land Development Code, which governs the unincorporated parish. 3, labeled Commentary, directs developers and property owners in unincorporated Ascension Parish to evaluate their fixture design against two scenarios. A no cutoff luminaire, where the light source has no cutoff point, defined in the code as the point at which all light emitted is completely eliminated at a specific angle to the ground, can produce unsightly glare and create a safety hazard.

A less than 90-degree cutoff luminaire is called preferable because the design of the fixture ensures the light source is not visible off site. This cutoff guidance sits alongside the mandatory Section 17-2088(A)(2) standard requiring parking-area, sign and structure lighting to deflect away from adjoining residential zones and streets. Lighting plans and specifications must be submitted as part of a development-permit site plan under Section 17-2090(E)(1)(g)(vii) whenever a site plan is required, letting the Zoning Official review fixture design, including cutoff angle, before a permit issues.

Every parking lot in the parish must also conform to these exterior lighting standards under Section 17-2081(F)(4). Because the parish's cutoff commentary is phrased as guidance rather than a numeric lumen or footcandle cap, there is no adopted dark-sky ordinance by that name for unincorporated Ascension Parish: the code stops at recommending cutoff fixtures rather than mandating a specific cutoff angle.

Violations & Fines

Ascension Parish enforces its Unified Land Development Code, including Section 17-2088, through the general penalty at Section 17-2090(W): any person, firm or corporation violating any provision is fined not less than $50.00 nor more than $500.00, or jailed up to 30 days, or both, and each day a violation continues is a separate offense. The Zoning Official can also flag noncompliant lighting during site plan or development-permit review and deny or revoke a permit.

Frequently Asked Questions

Does Ascension Parish require full cutoff outdoor lighting fixtures?
The Unified Land Development Code does not mandate full cutoff fixtures as a numeric requirement. Section 17-2088(A)(3) instead tells developers a less-than-90-degree cutoff luminaire is preferable because its design keeps the light source from being visible off site, while a no-cutoff fixture is flagged as producing unsightly glare and a safety hazard.
What is a cutoff fixture under the parish code?
Section 17-2088(A)(3) defines cutoff as the point at which all light emitted from a fixture is completely eliminated at a specific angle to the ground. A luminaire with less than a 90-degree cutoff angle is the design the code recommends for unincorporated Ascension Parish.
Who reviews outdoor lighting design before construction?
The Zoning Official reviews plans and specifications of proposed lighting as part of the site plan submitted with a development permit application under Section 17-2090(E)(1)(g)(vii), and every parking lot must conform to the Section 17-2088 lighting standards under Section 17-2081(F)(4).
What happens if a fixture violates the lighting standard?
Violations of the Unified Land Development Code, including Section 17-2088, carry the general penalty in Section 17-2090(W): a fine of $50.00 to $500.00, up to 30 days in jail, or both, with each day of a continuing violation counted as a separate offense.

Sources & Official References

Other rules in Ascension Parish

All Ascension Parish rules

Compare Ascension Parish to another location·View the Louisiana outdoor lighting overview

Get notified when Dark Sky Rules in Ascension Parish, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.