Hillsboro, OR Outdoor Lighting: Dark Sky Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Shielding trigger
>900 lumens (60W incandescent equivalent)
Required fixture
IESNA full cut-off, beam angle ≤90°
Max area lighting level
4 foot-candles at entries/pedestrian areas
Applies to
Type II/III development applications only
Relief mechanism
Variance/Adjustment under § 12.80.140
Last amended
Ordinance 6401, 2022

Summary

Hillsboro requires full cut-off shielding on any exterior fixture emitting more than 900 lumens (roughly a 60-watt incandescent bulb) on land that goes through Type II or Type III development review. The Community Development Code caps the fixture's beam angle at 90 degrees to cut glare onto neighboring property.

D.Light Trespass Standards.1.Light Trespass. Maximum lighting levels at property lines generally shall not increase lighting level more than 1.75 foot-candles 10 feet beyond the property line, as illustrated in Figure 12.50.240-A: [...] 2.Shielding. Any light source or lamp that emits more than 900 lumens (13 watt compact fluorescent or 60 watt incandescent) shall be concealed or shielded with an Illumination Engineering Society of North America (IESNA) full cut-off style fixture with an angle not exceeding 90 degrees to minimize the potential for glare and unnecessary diffusion on adjacent property.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Municipal Code: Supplement 1 | Community Development Code: Supplement 1).

Full Breakdown

140. A development application must include a lighting plan showing every fixture used to light streets, sidewalks, multi-use paths, parking lots, buildings and plazas, and the plan is checked against this section during land use review. On the functional side, pedestrian circulation areas need at least 2 foot-candles, required bicycle parking at least 3 foot-candles, and primary building entrances 3 to 4 foot-candles depending on proximity to a major transit stop, with an overall ceiling of 4 foot-candles for those same pedestrian, parking-lot entry and bike-parking areas.

2: any light source or lamp exceeding 900 lumens, the rough output of a 13-watt CFL or 60-watt incandescent bulb, must be concealed or fitted with an Illumination Engineering Society of North America (IESNA) full cut-off style fixture, with the light angle held to no more than 90 degrees, specifically to limit glare and stray light spilling onto adjacent lots. Fixtures also cannot be confused with warning, emergency, traffic, or airport lighting. m. The section was last amended by Ordinance 6401 in 2022, building on Ordinance 6322 (2019) and the original Ordinance 6120 (2015).

Violations & Fines

Because these standards are enforced through the land use approval, not a standalone citation, a lighting plan that omits required shielding blocks permit sign-off outright. Once approved, unshielded or over-lumen fixtures put the project out of compliance with its conditions of approval: HCDC § 12.70.120.H states failure to fulfill any condition of approval 'shall constitute a violation of this Code and the subject approval will be subject to code enforcement proceedings,' up to revocation of the approval itself. Relief runs through a Variance or Adjustment under § 12.80.140, not an after-the-fact waiver.

Frequently Asked Questions

Does Hillsboro require shielded, dark-sky-friendly light fixtures?
Yes, but only for lighting tied to a Type II or Type III development application. Any fixture over 900 lumens (about a 60-watt incandescent bulb) must use an IESNA full cut-off fixture with the beam held to 90 degrees or less, per HCDC § 12.50.240(D)(2).
Does the shielding rule apply to an existing single-family house in Hillsboro?
Not directly. Section 12.50.240 attaches to Type II and Type III land use applications, meaning new construction, redevelopment, or projects requiring that level of review; routine lighting on an existing single-family lot outside that process is not reviewed under this section.
Can a business floodlight its parking lot without limit?
No. Parking-lot and pedestrian-area lighting reviewed under § 12.50.240 is capped at 4 foot-candles, and any fixture over 900 lumens still needs full cut-off shielding regardless of where it sits on the site.
Is stadium or sports-field lighting exempt from the shielding standard?
It is exempt from the general section, but only if poles stay at 80 feet or under, light at the property line stays below 2 foot-candles, and the lights shut off by 11:00 p.m., per HCDC § 12.50.240(E)(7).

Sources & Official References

Other rules in Hillsboro

All Hillsboro rules

Compare Hillsboro to another location·View the Oregon outdoor lighting overview

Get notified when Dark Sky Rules in Hillsboro, OR changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Dark Sky Rules in Nearby Cities

How other cities in Washington County handle dark sky rules.

Beaverton, OR
Some Restrictions