Skip to main content
CityRuleLookup

Lynchburg, VA Outdoor Lighting: Dark Sky Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Fixture standard
Full cut-off, fully shielded light source
Exempt uses
Single-household and duplex dwellings
Review point
Required on site plan/CUP lighting plans
Alternate height cap
25 ft residential, 35 ft business/industrial
Holiday exception
Nov. 15 to Jan. 15 each year

Summary

Lynchburg requires nearly all new exterior lighting on non-residential and multi-household properties to use full cut-off fixtures with the light source completely shielded, and to be installed so no direct light crosses a residential property line, under Zoning Ordinance Sec. 35.2-65.3(a).

(a)Shielding Required. All exterior lighting shall be full cut-off fixtures with the light source fully shielded, with the exception of unshielded luminaires installed pursuant to paragraph (c) of this section. All other lighting shall be installed so that the direct lighting from fixtures is shielded from crossing any residential property line.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 10).

Full Breakdown

Lynchburg's outdoor lighting chapter, Sec. 2-65, applies to all permanent exterior lighting installed on private property after its effective date, with the single exception of single-household and duplex dwellings, which Sec. 2(b) exempts outright. For everything else, from a commercial parking lot to a multi-household apartment complex, Sec. 3(a) sets the baseline shielding rule: every exterior fixture must be a full cut-off fixture with its light source completely shielded, and even fixtures that qualify for the limited exception in paragraph (c) for unshielded luminaires still must not let direct light cross a residential property line.

The purpose section, Sec. 1, frames these standards as balancing glare control against safe roadways and efficient lighting, and the applicability section requires every final site plan or conditional use permit application to include a lighting plan showing the location, type, height, and lumen output of every fixture, so the shielding requirement is checked before a certificate of occupancy issues rather than after complaints arrive. Fixtures that do not achieve a full cutoff, but that still cut off light at 90 degrees or less and shield it from abutting residential property, fall under the alternative height-based standards in paragraph (d) and Exhibit VI-16, capping mounting height at 25 feet in residential districts and 35 feet in business, institutional, and industrial districts.

A property owner may exceed those heights only by submitting a master lighting plan certified by a qualified lighting professional showing that spillover at the property lines will still stay within the thresholds set in Sec. 3. The chapter carves out one calendar exception: holiday lighting between November 15 and January 15 each year is not subject to any of these shielding or height standards under Sec. 2(d).

Violations & Fines

A commercial or multi-household property installing exterior lighting without full cut-off fixtures, or lighting that allows direct light to cross a residential property line, is out of compliance with Sec. 35.2-65.3(a) and can be denied a certificate of occupancy under the documentation requirement in Sec. 35.2-65.4(c)(3). An existing violation identified after occupancy is enforced through the Sec. 35.2-102 process, carrying a misdemeanor fine of up to $1,000 under Sec. 35.2-102.2 if not corrected after notice.

Frequently Asked Questions

Does every business in Lynchburg have to use full cut-off light fixtures?
Every use except single-household and duplex dwellings, under Sec. 35.2-65.2(b) and Sec. 35.2-65.3(a). Commercial, institutional, industrial, and multi-household properties must use full cut-off fixtures with the light source completely shielded.
When does Lynchburg check for full cut-off fixtures?
At the site plan or conditional use permit stage: Sec. 35.2-65.2(a) requires a lighting plan showing every fixture's location, type, height, and lumen output before final approval, and Sec. 35.2-65.4(c)(3) requires documentation of compliance before a certificate of occupancy issues.
Can a fixture that is not full cut-off ever be used?
Yes, if it meets the alternative standard in Sec. 35.2-65.3(d): a cutoff of 90 degrees or less, shielded from abutting residential property, and within the height caps of 25 feet in residential districts or 35 feet in business and industrial districts.
Are holiday lights exempt from the shielding rules?
Yes. Sec. 35.2-65.2(d) exempts holiday lighting displayed between November 15 and January 15 each year from the outdoor lighting chapter's shielding and height standards entirely.

Sources & Official References

Other rules in Lynchburg

All Lynchburg rules

Compare Lynchburg to another location·View the Virginia outdoor lighting overview

Get notified when Dark Sky Rules in Lynchburg, VA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.