Lynchburg, VA Outdoor Lighting: Dark Sky Rules (2026)
Key Facts
- Fixture standard
- Full cut-off, fully shielded light source
- Exempt uses
- Single-household and duplex dwellings
- Review point
- Required on site plan/CUP lighting plans
- Alternate height cap
- 25 ft residential, 35 ft business/industrial
- Holiday exception
- Nov. 15 to Jan. 15 each year
Summary
Lynchburg requires nearly all new exterior lighting on non-residential and multi-household properties to use full cut-off fixtures with the light source completely shielded, and to be installed so no direct light crosses a residential property line, under Zoning Ordinance Sec. 35.2-65.3(a).
(a)Shielding Required. All exterior lighting shall be full cut-off fixtures with the light source fully shielded, with the exception of unshielded luminaires installed pursuant to paragraph (c) of this section. All other lighting shall be installed so that the direct lighting from fixtures is shielded from crossing any residential property line.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 10).
Full Breakdown
Lynchburg's outdoor lighting chapter, Sec. 2-65, applies to all permanent exterior lighting installed on private property after its effective date, with the single exception of single-household and duplex dwellings, which Sec. 2(b) exempts outright. For everything else, from a commercial parking lot to a multi-household apartment complex, Sec. 3(a) sets the baseline shielding rule: every exterior fixture must be a full cut-off fixture with its light source completely shielded, and even fixtures that qualify for the limited exception in paragraph (c) for unshielded luminaires still must not let direct light cross a residential property line.
The purpose section, Sec. 1, frames these standards as balancing glare control against safe roadways and efficient lighting, and the applicability section requires every final site plan or conditional use permit application to include a lighting plan showing the location, type, height, and lumen output of every fixture, so the shielding requirement is checked before a certificate of occupancy issues rather than after complaints arrive. Fixtures that do not achieve a full cutoff, but that still cut off light at 90 degrees or less and shield it from abutting residential property, fall under the alternative height-based standards in paragraph (d) and Exhibit VI-16, capping mounting height at 25 feet in residential districts and 35 feet in business, institutional, and industrial districts.
A property owner may exceed those heights only by submitting a master lighting plan certified by a qualified lighting professional showing that spillover at the property lines will still stay within the thresholds set in Sec. 3. The chapter carves out one calendar exception: holiday lighting between November 15 and January 15 each year is not subject to any of these shielding or height standards under Sec. 2(d).
Violations & Fines
A commercial or multi-household property installing exterior lighting without full cut-off fixtures, or lighting that allows direct light to cross a residential property line, is out of compliance with Sec. 35.2-65.3(a) and can be denied a certificate of occupancy under the documentation requirement in Sec. 35.2-65.4(c)(3). An existing violation identified after occupancy is enforced through the Sec. 35.2-102 process, carrying a misdemeanor fine of up to $1,000 under Sec. 35.2-102.2 if not corrected after notice.
Frequently Asked Questions
Does every business in Lynchburg have to use full cut-off light fixtures?
When does Lynchburg check for full cut-off fixtures?
Can a fixture that is not full cut-off ever be used?
Are holiday lights exempt from the shielding rules?
Sources & Official References