Porterville, CA Outdoor Lighting: Dark Sky Rules (2026)
Key Facts
- Purpose
- protect night sky and astronomy
- Fixture standard
- IESNA Cut Off / Full Cut Off
- Max fixture height
- 16 ft residential, up to 50 ft REC/PK
- Mercury vapor lighting
- not permitted
- Exempt
- fixtures under 4,050 lamp lumens
- Applies to
- fixtures installed after ordinance took effect
Summary
In the City of Porterville, Municipal Code Section 300.07 exists to protect the night sky, requiring every outdoor light fixture installed after the ordinance took effect to be shielded to IESNA "Cut Off" or "Full Cut Off" standards, with shielding and filtering keyed to the lamp type in Table 300.07(B).
A. Purpose. This section is intended to minimize outdoor artificial light that may have a detrimental effect on the environment, astronomical research, amateur astronomy, and enjoyment of the night sky. ... ... E. Shielding. All lighting fixtures shall be shielded in accordance with Table 300.07(B) so as not to produce obtrusive glare onto the public right-of-way or adjoining properties. All luminaries shall meet the most recently adopted criteria of the Illuminating Engineering Society of North America (IESNA) for “Cut Off” or “Full Cut Off” luminaries, as illustrated in Figure 300.07.
Full Breakdown
Section 300.07.A states the purpose in explicitly astronomical terms: the shielding rules exist to minimize outdoor artificial light that could harm the environment, astronomical research, amateur astronomy and enjoyment of the night sky, not just to control glare for neighbors. That purpose becomes a design standard in Section 300.07.E, which requires every fixture to meet the Illuminating Engineering Society of North America's "Cut Off" or "Full Cut Off" criteria and to be shielded according to Table 300.07(B).
The shielding table sorts fixtures by lamp type. LED and fluorescent fixtures need full shielding plus filtering; high-pressure sodium and quartz lamps need full shielding with no filtering requirement; low-pressure sodium, described in the code as the source preferred for minimizing light pollution affecting astronomical observations, needs neither; and mercury vapor fixtures are not permitted at all. Maximum fixture height is separately capped by Table 300.07(A), from sixteen feet in residential districts up to fifty feet in recreation and park districts.
The rules apply going forward: Section 300.07.B limits the requirements to fixtures installed after the ordinance's effective date, and a property is grandfathered unless fifty percent or more of its existing fixtures get replaced, at which point the whole installation has to come into compliance. Fixtures under 4,050 total lamp-source lumens, fossil-fuel-combustion lighting, and temporary construction or emergency lighting are exempt outright.
Violations & Fines
The Zoning Administrator enforces fixture shielding and height as part of building-permit and code-enforcement review; a light installed after the effective date without the required IESNA cutoff shielding, or a mercury vapor fixture, is a nonconforming installation the property owner must replace or retrofit. Unshielded LED or fluorescent lighting missing the filtering Table 300.07(B) requires can also be cited.
Frequently Asked Questions
Does Porterville require outdoor lights to be shielded?
Why does Porterville's lighting code mention astronomy?
Are older outdoor lights in Porterville exempt from the shielding rule?
Sources & Official References
Other rules in Porterville
California rules heatmap·Compare Porterville to another location·View the California outdoor lighting overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.